Specifications – Atec Agilent-6690A-6692A User Manual

Page 3

Advertising
background image

Parameter

Agilent Model Number
6690A

6691A

6692A

Output Ratings

Voltage:

0-15 V

0-30 V

0-60 V

Current:*

0-440 A

0-220 A

0-110 A

*Derated linearly 1%/°C from

40°C to 55°C

Programming Accuracy (@ 25 ±5°C)

Voltage:

0.04% +

15 mV

30 mV

60 mV

Current:

0. l % +

230 mA

125 mA

65 mA

Ripple & Noise

(from 20 Hz to 20 MHz with
outputs ungrounded, or with
either output terminal grounded)

Constant Voltage:

rms

2.5 mV

2.5 mV

1.5 mV

Constant Voltage:

p-p

15 mV

25 mV

25 mV

Constant Current:**

rms

200 mA

50 mA

30 mA

**With load inductance >5 µH.

Readback Accuracy

(from front panel or over GPIB
with respect to actual output
@ 25 ±5°C)

Voltage:

0.05% +

22.5 mV

45 mV

90 mV

±Current:

0.1% +

300 mA

165 mA

80 mA

Load Regulation

(change in output voltage or
current for any load change
within ratings)

Voltage

0.002% +

650 µV

1.1 mV

2.2 mV

Current:

0.005% +

40 mA

17 mA

9 mA

Line Regulation

(change in output voltage or current
for any line change within ratings)

Voltage:

0.002% +

650 µV

650 µV

650 µV

Current:

0.005% +

40 mA

17 mA

9 mA

Transient Response Time

(for the output voltage to recover
to within 150 mV following any step
change from 100% to 50% or 50% to
100% of the rated output current): <900 µs

Specifications

Advertising