Kdc series : specifications – Atec Argantix-KDC Series User Manual

Page 2

Advertising
background image

www.ProgrammablePower.com

64

KDC Series : Specifications

Output

Power: Maximum 5, 10 or 15 KW
Voltage: Line Regulation: < 0.1% of Range
Load Regulation: < 0.1% of Range
Accuracy: ± 0.05% Setting + 0.1% Range
Transient Response: Voltage will recover to within

2% of voltage range within 2 msec for

a 30 % load step.

Stability: ± 0.05% of max. rating per 8 hours

after 30 mins warmup at fixed line,

load and temperature.

Current
Line Regulation: < 0.1% of Range
Load Regulation: < 0.1% of Range
Accuracy: ± 0.05% Setting + 0.1% Range
Stability: ± 0.05% of setting after 8 hour

warmup at fixed line, load and

temperature.

Input

Voltage: 208 - 10 % to 230 + 10% VAC

400 ± 10 % VAC

480 ± 10 % VAC

All inputs are L-L, 3 phase, 3- wire plus

safety ground. Input rating must be

specified at time or order.

Current RMS: Typical RMS current per phase at

low line input voltage.

Power Factor: > 0.65
Efficiency: > 85 % at full load.

Measurements

Voltage
Accuracy: 0.05% + 0.1% Full Scale
Resolution: 0.025% Full Scale

Current
Accuracy: 0.1% + 0.2% Full Scale
Resolution: 0.025% Full Scale

Power
Accuracy: 0.2% + 0.3% Full Scale
Resolution: 0.05% Full Scale

Protection
Over temperature, short circuit, over current
protection, open sense.

Controls and Indicator
Controls: Dual digitally encoded rotary knobs,

Function keys, Output on/off, Power

on/off

Indicators
Display: Alphanumeric LCD, dual line.
LED’s for: Output on/off, CC mode, CV mode,

CP mode and Remote.

Remote Control
A standard RS232C is included with all KDC
Series DC Power Supplies. An optional GPIB/IEEE-
488 with analog RPV (0-10 VDC) input is available
as well.

RS232C / RS485 - Standard
9 pin D-shell connector, 115200 baud max.,
SCPI syntax.

-IF option:
IEEE-488 Interface
IEEE-488 (GPIB) talker listener.
Subset: AH1, C0, DC1, DT1, L3, PP0, RL2,

SH1, SR1, T6

IEEE-488.2 SCPI syntax

Analog interface:
Voltage control: 0-10 VDC, 0-5 VDC or R for

0-100% range

Current control: 0-10 VDC, 0-5 VDC or R for

0-100% range

I/O Connectors: Analog I/O, 15 Pin D-sub, isolated

Auxiliary I/IO, 9 Pin D-sub nonisolated.

Functions:

Remote Output On/Off

Trigger Input

Function strobe out.

Volt Monitor out

Current Monitor out

Environmental

Temperature Coefficient
Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range

Ambient Temperature
Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F

Humidity
Operating: 0 to 80% RH, non condensing

Cooling
Forced air, side and top intake, rear exhaust.

Power Level

Vlow

5 kW

10 kW

15 kW

187 V

27 A

54 A

81 A

360 V

15 A

30 A

45 A

432 V

12 A

24 A

36 A

© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries.
Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.

Advertising