Ets terrasas - specifications – Atec Elgar-ETS Series User Manual

Page 4

Advertising
background image

www.ProgrammablePower.com

Photovoltaic array modeling

Specifications

Model Number

1

ETS60X14C

ETS80X10.5C

ETS150X5.6C

ETS80X15C

ETS600X _ _

ETS1000 X10

Output voltage, Voc (V)

60

80

150

80

600

1000

Output current, Isc (A)

14

10.5

5.6

15

8.3, 16.7, 25

10

Output power @ 0.85FF (W)

714

714

714

1020

4250, 8500, 12750

8500

MPP tracking speed (Hz)

2

250

250

250

120

200

200

I-V curve resolution (# of pts)

1024

1024

1024

1024

1024

1024

Output capacitance

< 10nF

< 10nF

< 10nF

< 70uF

< 70uF

< 3uF

Output isolation (Vpk)

±1000

±1000

±1000

± 600

± 600

± 1400

Available I/O

Ethernet

Ethernet

Ethernet

Ethernet

Ethernet

Ethernet

Remote sense

2V

2V

2V

2V

10V

10V

AC Input Voltage, V

(max operational range)

85-264VAC

85-264VAC

85-264VAC

100-130VAC low

170-230VAC high

C: 187-242VAC

D: 342-440 VAC

E: 396-528 VAC

C: 187-242VAC

D: 342-440 VAC

E: 396-528 VAC

Input frequency, Hz

47-63

47-63

47-63

47-63

47-63

47-63

Power factor

> 0.99 typical

> 0.99 typical

> 0.99 typical

> 0.7 typical

> 0.9 typical

> 0.9 typical

Output voltage noise

Measured across a 1μF capacitor at
the end of a 1.8m(6ft) line at full
load, 20MHz

< 0.35 Vpp

< 0.35 Vpp

< 0.6 Vpp

< 1 Vpp

< 0.6 Vpp

< 0.6 Vpp

Output current noise

Measured with hall effect sensor,
BW = 650kHz

< 60 mApp

< 60 mApp

< 60 mApp

< 100 mApp

< 200 mApp

< 200 mApp

Operating temperature

0-40 degs C

0-40 degs C

0-40 degs C

0-50 degs C

0-50 degs C

0-50 degs C

Physical dimensions

22.6 x 1.7 x 19.0 in

574 x 43.6 x 483 mm

21 lbs (9.5 kg)

22.6 x 1.7 x 19.0 in

574 x 43.6 x 483 mm

21 lbs (9.5 kg)

22.6 x 1.7 x 19.0 in

574 x 43.6 x 483 mm

21 lbs (9.5 kg)

20.4 x 1.7 x 19.0 in

518 x 43.6 x 483 mm

23 lbs (10.5 kg)

25.5 x 5.3 x 19.0 in

64.7 x 13.3 x 48.3 cm

5kW 40 lbs (18 kg)
10kW 60lbs (27kg)

15kw 80lbs (36kg)

25.5 x 5.3 x 19.0 in

64.7 x 13.3 x 48.3 cm

10kW 60lbs (27kg)

Regulatory

Certified to UL/CSA 61010 and IEC/EN 61010-1

Notes
1 See next page for full listing of model numbers and configurations
2 Maximum MPPT rate of the inverter under test. Closed loop analog output bandwidth is much greater.

ETS TerraSAS - Specifications

Photovoltaic array modeling
This feature allows the user to quickly define
an array of PV panels connected in series or
parallel. Using this array modeling capability, the
user can simulate such real world conditions as

mismatched panels, which result in multiple hump
I-V curves. It is important to verify that the MPPT
algorithm finds and settles on the universal MPP,
not a local maximum.

Import module data

from embedded

Sandia database and

create I-V Curve

Build the array model by

binding to the desired

curve and specifying the

array size

The effects of shadowing, aging and faulty modules

can be previewed in real time. the resulting I-V

curve can be dragged and dropped to any output

for inverter testing.

294

Advertising