5.3 Typical Specifications

Typical specifications as listed in Table 37 are not warranted but are descriptions of
typical performance determined either by design or type testing.

Parameter

CI 3000iL

CI 4500iL

CI 4801iL

Input Ratings

Maximum Input Current (rms):

180 -254 Vac (3Ø)

18 A

25 A

360-440 Vac (3Ø)

10 A

15 A

Maximum Input Power:

5800 VA/4100 W

8900 VA/5900 W

Output Isolation Voltage:

300 V rms

Average Programming Accuracy:

rms current

0.2% + 40 mA 3Ø
0.2% + 80 mA 1Ø

0.2% + 80 mA

Average Programming Resolution

rms Voltage:

80 mV

Overvoltage Programming (OVP):

2 V

rms Current:

2.5 mA 3Ø
7.5 mA 1Ø

2.5 mA 3Ø
7.5 mA 1Ø

7.5 mA

Output Frequency:

0.001 Hz

Phase:

0.001º

Average Measurement Resolution

rms Voltage:

10 mV

rms Current:

6 mA 3Ø
5 mA 1Ø

1.2 mA

Time values

List Dwell Time:

0 - 1.08 X 10

6

s

0 - 4.30 X 10

5

s

Triggering Accuracy With Respect to Phase
Synchronization:

250 s

100 s

Trigger In Response Time:

400 s

200 s

Minimum Resolution for Dropout:

500 s

Output Response Time: (output change from
10% to 90% or 90% to 10% of its total
excursion with full resistive load)

50 s

Remote Inhibit Response Time:

<1 ms

Harmonic Measurement Time:

1 harmonic 100 ms;

all 50 harmonics 2 s

Miscellaneous

Recommended Calibration Interval:

1 year

Remote Sense Capability:

Up to 10 Vrms can be dropped across each load lead.

Waveform Table Horizontal Resolution:

1024 points

Trigger In / Out characteristics

Trig Out (HC TTL output):

V

ol

0.8 V max. @ 1.25 mA

V

oh

3.3 V max. @ 1.25 mA

Trig In (10 k pullup):

V

il

0.8 V max. V

ih

2 V min.

INH/FLT Characteristics

Maximum ratings:

16.5 VDC between INH terminals; FLT terminals; and

from INH terminals to chassis ground

INH terminals:

I

ol

1.25 mA max.

V

ol

0.5 V max.

FLT terminals

V

il

0.8 V max.

V

ih

2 V min.

tw 100 µs min.
td 4 ms typical

Saveable Data (nonvolatile)

Instrument States:

16 (0 to 15)