3

JD725A CABLE AND ANTENNA ANALYZER

Main Functions

VSWR / Return Loss

VSWR and Return Loss measurements provide the impedance per-

formance and signal reflection characteristics of cable, connectors, and

antenna systems.

Frequency range: 25 to 4000MHz

•

Dynamic Range: 60dB

•

Over 80 wireless frequency bands built-in in the instrument’s data-

•

base

Flexibility to incorporate additional frequency bands

•

User definable limit line for

•

DTF (Distance to Fault)

The DTF measurement function allows user to accurately identify faulty

locations.

Frequency range: 25 to 4000MHz

•

Distance: Up to 1250m (4125ft)

•

Dynamic Range: 60 dB

•

High resolution mode with 1001 points

•

Over 95 cable types built-in in the instrument’s database

•

Flexibility to incorporate additional cable types

•

User definable limit line for fast Pass/Fail characterization

•