Peak kilovolts, Cable capacitance microfarads, Output peak milliamperes – Atec High-Voltage-VLF-28CMF User Manual

Page 5

Advertising
background image

PEAK

KILOVOLTS

0

60

CABLE CAPACITANCE

MICROFARADS

0

60

0

6.0

OUTPUT PEAK MILLIAMPERES

SCOPE

POS

NEG

60

30

10

METER

μF

mA

CAPACITANCE

SCALE X10

PUSH TO READ

X1

CAP

ZERO

5

Input:

230 V, 50/60 Hz, 30A peak, 25A average

Output:

0-65 kVac peak, 0.1/0.05/0.02/0.01 Hz sinusoidal

Duty:

Continuous

Load Rating:

2.2 mF @ 0.1 Hz, 4.4mF @ 0.05 Hz

11 mF @ 0.02 Hz & 22 mF @ 0.01 Hz

Metering:

Voltmeter: 0-75 kVac peak

Charging Current Meter: 0 – 200 mA peak

Load capacitance meter: 0 – 6 microfarads

User programmable test duration timer

Cable Lengths: Shielded EPR output cable - 100 ft. (30m)

Ground cable 100 ft. (30m)

Sizes & Weight: Controls: 17” w x 11” d x 9.5” h, 20 lbs.

432mm w x 280mm d x 241mm h, 9 kg

Regulator: 20” w x 14” d x 27” h, 160 lbs.

508mm w x 356mm d x 686mm h, 73 kg

HV Tank: 15” w x 18” d x 22” h, 215 lbs.

381mm w x 457mm d x 559mm h, 98 kg

Overall:

30” w x 60” d x 51” h, 704 lbs.

762mm w x 1524mm d x 1295mm h, 320 kg

VLF-65CMF

The VLF-65CMF, 65 kVpeak output, is a higher power model designed to test

very long cables rated up to 35kV. It offers the complete controls package including

Cable Burn mode. Its cable reels provide 100’ (30m) of HV and ground cable.

VLF-90CMF

The

VLF-90CMF offers 90kVac peak output voltage, suitable for testing

cables rated 45 – 50kV. It is load rated for 0.55

m

F @ 0.1Hz, capable of test-

ing up to 2 miles of cable, five times that at 0.02Hz. Pictured with optional

hand truck.

Input:

230 V, 50/60 Hz, 20A peak, 15A average

Output:

0-90 kVac peak, 0.1/0.05/0.02 Hz sinusoidal

Duty:

Continuous

Load:

.55 mF @ 0.1 Hz

1.1 mF @ 0.05 Hz

2.75 mF @ 0.02 Hz

Metering:

Voltmeter: 0-100 kVac peak

Current Meter: 0 – 100 mA peak

Load capacitance: 0 – 6 microfarads

User programmable test duration timer

Cable Lengths: Shielded EPR output cable – 20 ft. (6m)

Interconnect cable - 10 ft. (3m)

Sizes & Weights: Control: 26” w x 13” d x 16” h, 75 lbs.

660 mm w x 330 mm d x 406 mm h, 34 kg

HV Tank: 15” w x 21” d x 29” h, 293 lbs.

381 mm w x 533 mm d x 737 mm h, 133 kg

Input:

230V +/-10%, 50/60 Hz, single phase, 30 A peak, 25 A avg.

Output:

Sinusoidal 0-50 kVac peak, 0.1, .05, .02 and .01 Hz frequency

Duty:

Continuous

Test Capacitance:

5.0mF @ .1 Hz, 10.0mF @ .05 Hz, 25.0 mF @ .02 Hz, [email protected] Hz

Minimum capacitance to achieve full output – .01 mF

Kilovoltmeter: 3.5 in., 0-60 PEAK KILOVOLTS 2% FS Accuracy

Current Load:

3.5 in., 0-200 MILLIAMPERES 5% FS Accuracy

Capacitance Meter:

0-6 mF with x1 & x10 ranges

Sizes:

Remote Control: 17” w x 11” d x 9.5” h, 20 lbs.

432mm w x 280mm d x 241mm h, 9 kg

Power Section: 20” w x 14” d x 27” h, 160 lbs.

508mm w x 356mm d x 686mm h, 73 kg

HV Tank size:

13.5” w x 19” d x 23” h, 310 lbs.

343mm w x 483mm d x 584mm h, 141 kg

Complete Trolley: 28” w x 60” d x 51” h, 775lbs

711mm w x 1524mm d x 1295mm h, 352 kg

Output cable

length:

Shielded X-Ray/Ground on reels - 100ft.

VLF-50CMF

The VLF-50CMF is the highest power VLF unit we offer. It is rated for 5 mF at 0.1 Hz and can increase its output to 50 mF at 0.01

Hz, capable of testing up to 50 miles of 15 kV and 25 kV cable. It is ideal for very long cable runs, like long feeders, wind farm

applications, submarine cables, and others. It comes as pictured, including a cable reels with 100’ of high voltage and ground cable.

Remove the wheels for van mounting.

Simple installation – ready to go.

VLF-65CMF

Wind Farm

Model

VLF-50CMF

Remove

wheels

for van

mounting

Only portable

unit at 90 kV