Electric and magnetic field measurement, Narda, Excellence – Atec Narda-EMR-300 User Manual

Page 4

Advertising
background image

USA TEL: (1) 631 231-1700 • FAX: (1) 631 231-1711 • E-MAIL: [email protected]www.narda-sts.com
GERMANY TEL: 49-7121-9732-777 • FAX: 49-7121-9732-790 • E-MAIL: [email protected]www.narda-sts.de

Electric and Magnetic Field Measurement

50 Years of

Excellence

RF Safety

Test Solutions

an

communications company

narda

Safety Test Solutions

34

Linearity

c

Isotropic

Deviation

d

Overload

Limit

H-field

Suppression

Thermal

Response

e

Dimensions

Diameter,

Length

±3 dB (0.6 to 1.25 V/m)

±1.0 dB (1.25 to 2.5 V/m)

±0.5 dB (2.5 to 400 V/m)

±0.7 dB (400 to 800 V/m)

±1.0 dB for

f > 1 MHz

700 mW/cm

2

,

70 W/cm

2

>45 dB (300 kHz)

>35 dB (1 MHz)

>20 dB

(above 5 MHz)

+0.2 / -1.5 dB

64 mm,

310 mm

±0.5 dB (1.2 to 200 V/m)

±0.7 dB (200 to 320 V/m)

±1.0 dB

175 mW/cm

2

,

17.5 W/cm

2

>20 dB (Typ.)

+0.2 / -1.5 dB

75 mm,

310 mm

±3dB (0.8 to 1.65 V/m)

±1.0 dB (1.65 to 3.3 V/m)

±0.5 dB (3.3 to 300 V/m)
±8 dB (300 to 1000 V/m)

±1.5 dB

(10 MHz to 8 GHz)

±2.0 dB

(f > 8 GHz)

700 mW/cm

2

,

70 W/cm

2

> 20 dB

±0.8 dB

64 mm,

310 mm

+2/-3 dB (1.0 to 2.0 V/m)

±1.0 dB (2 to 250 V/m)

±1.0 dB

1600 V/m,

1 W/cm

2

>20 dB (Typ.)

±0.8 dB

64 mm,

310 mm

±3 dB (0.3 to 1.3%)
±1.0 dB (1.3 to 5%)

±0.5 dB (5 to 10,000%)

+3.0 dB/- 0.5 dB

(10 to 300 MHz)

±1.0 dB

(300 MHz to 1 GHz)

±2.0 dB

(1 to 12 GHz)

32 dB

(< 10kV/m),

50 dB

(< 100 kV/m)

>45 dB (300 kHz)

>35 dB (1 MHz)

>20 dB

(above 5 MHz)

+0.8 /- 1.0 dB

64 mm,

310 mm

±0.5 dB (39 to 614 V/m)

±1.0 dB

0.6W/m

2

,

200 W/m

2

N/A

±0 dB

64 mm,

310 mm

Notes:

a

Typical performance data

b

Type 25 is shaped to FCC limits for "Controlled Occupational" environments,
Type 26 probe is shaped to Canadian Safety Code 6 (RF/microwave workers) and recommendations of ICNIRP for occupational exposures.

c

Linearity referred to 27.5 V/m at 27.12 MHz (27.5 V/m and 100 MHz for Type 9C, 27.5 V/m for Type 11C
and 50% of standard and 100 MHz for Types 25C and 26C) where there is an absolute error of ±1.0 dB

d

Includes EMR meter, Typical

e

0 to +50°C, except Types 11C, 25C and 26C which are -10 to +50°C

Advertising