Ts series iv specifi cations, 3u to 9u rack-mount power supplies – Atec Magna-Power_TSD Series User Manual

Page 4

Advertising
background image

www.magna-power.com

11

3U to 9U Rack-Mount Power Supplies

Input Specifi cations

Nominal Voltage
3 phase, 3 wire + ground

208 Vac, 3Φ (operating range 187 - 229 Vac)
240 Vac, 3Φ (operating range 216 - 264 Vac)
380 Vac, 3Φ (operating range 342 - 418 Vac)
415 Vac, 3Φ (operating range 373 - 456 Vac)
440 Vac, 3Φ (operating range 396 - 484 Vac)
480 Vac, 3Φ (operating range 432 - 528 Vac)

1 phase, 2 wire + ground
(5 kW Models Only)

208 Vac, 1Φ (operating range 187 - 229 Vac)
240 Vac, 1Φ (operating range 216 - 264 Vac)

Frequency

50 Hz - 400 Hz (operating range 45 - 440 Hz)

Power Factor

> 0.92 at maximum power for 3Φ units
> 0.70 at maximum power for 1Φ units

Output Specifi cations

Ripple

(See Model Charts)

Line Regulation

Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale

Load Regulation

Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale

Load Transient Response

2 ms to recover within ±1% of regulated output, with a
50% to 100% or 100% to 50% step load change

Effi

ciency

≥ 86% at full load (See Model Charts)

Stability

± 0.10% for 8 hrs. after 30 min. warmup

Isolation

User inputs and outputs: referenced to earth ground.

Maximum input voltage to ground: ±2500 Vac.

Maximum output voltage to ground:
±1000 Vdc for models less than or equal to 1000 Vdc
±(2000 Vdc + Vo/2) for models greater than 1000 Vdc or
with High Isolation Option (+ISO) where Vo is the unit’s
output voltage maximum

Maximum Slew Rate

Standard Models:
100 ms for output voltage change from 0 to 63%
100 ms for output current change from 0 to 63%

With High Slew Rate Option (+HS):
4 ms for output voltage change from 0 to 63%
8 ms for output current change from 0 to 63%

Bandwidth

Standard Models:
3 Hz for remote analog voltage programming
2 Hz for remote analog current programming

With High Slew Rate Option (+HS):
60 Hz for remote analog voltage programming
45 Hz for remote analog current programming

Control Specifi cations

Voltage Programming Accuracy

± 0.075% of full scale voltage

OVT Programming Accuracy

± 0.075% of full scale voltage

Current Programming Accuracy

± 0.075% of full scale current

OCT Programming Accuracy

± 0.075% of full scale current

Voltage Readback Accuracy

± 0.2% of full scale voltage

Current Readback Accuracy

± 0.2% of full scale current

External Analog Programming and
Monitoring Levels

0 - 10 Vdc

External Analog Output Impedances

Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10 Vdc reference: 1 Ω

External Digital Programming and
Monitoring Limits

Input: 0 to 5 Vdc, 10 kΩ input inpedance
Output: 0 to 5 Vdc, 5 mA drive capacity

Remote Sense Limits

3% maximum voltage drop from output to load

Environmental Specifi cations

Ambient Operating Temperature

0 °C to 50 °C

Storage Temperature

-25 °C to 85 °C

Humidity

Relative humidity up to 95% non-condensing

Temperature Coeffi

cient

0.04 % / °C of maximum output voltage
0.06 % / °C of maximum output current

Air Flow

Side air inlet, rear exhaust

Water Cooling (+WC Option)
(Diagrams Available)

Inlet temperature: 25°C
Flow rate (minimum): 1.5 GPM for 15 kW units
3.0 GPM for 20 to 30 kW units
4.5 GPM for 45 kW units
80 PSI maximum pressure

Physical Specifi cations

Power

Size (H” x W” x D”)

Rack Units

Weight

5 kW

5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

3U

74 lbs (33.60 kg)

10 kW

5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

3U

94 lbs (42.64 kg)

15 kW

5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

3U

114 lbs (51.71 kg)

20 kW

10.25 x 19 x 24 in (26.0 x 48.3 x 61.0 cm)

6U

197 lbs (89.36 kg)

25 kW

10.25 x 19 x 24 in (26.0 x 48.3 x 61.0 cm)

6U

217 lbs (98.43 kg)

30 kW

10.25 x 19 x 24 in (26.0 x 48.3 x 61.0 cm)

6U

237 lbs (107.50 kg)

45 kW

15.75 x 19 x 24 in (40.0 x 48.3 x 61.0 cm)

9U

349 lbs (158.30 kg)

TS Series IV Specifi cations

Note: Specifi cations are subject to change without notice. For three-phase confi gurations,

input specifi cations are line-to-line. Unless otherwise noted, input voltages and cur-
rents are specifi ed for three-phase confi gurations.

Output Current (Adc)

Output V

oltage

(V

dc)

(Voltage Maximum, Current Maximum)

Output Operation Region