XR SERIES II

Specifications

M

AGNA-POWER

ELECTRONICS

M

E

P

Input

Nominal Voltage

3 phase, 3 wire + ground

208 VAC, 3φ (operating range 187 - 229 VAC)
240 VAC, 3φ (operating range 216 - 264 VAC)
380 VAC, 3φ (operating range 342 - 418 VAC)
415 VAC, 3φ (operating range 373 - 456 VAC)
440 VAC, 3φ (operating range 396 - 484 VAC)
480 VAC, 3φ (operating range 432 - 528 VAC)

1 phase, 2 wire + ground
(2 kW models only)

208 VAC, 1φ (operating range 187 - 229 VAC)
240 VAC, 1φ (operating range 216 - 264 VAC)

Frequency

50 Hz through 400 Hz

Power Factor

Greater than 92% at maximum power

Environmental

Operating Temperature

0 °C to 50 °C

Storage Temperature

-25 °C to 85 °C

Temperature Coefficient

0.04 / °C of maximum output current

Air Cooling

Side air inlet, rear exhaust

Programming Levels and Accuracy of Full Scale

Voltage

Set Point

Current

Set Point

OVT

Set Point

OCT

Set Point

Remote Analog

Programming Accuracy

± 0.50%

± 0.75%

± 0.50 %

± 0.75%

Digital

Programming Accuracy

± 0.50%

± 0.75%

± 0.50 %

± 0.75%

Remote Analog

Programming Levels

0 - 10.0 V

0 - 10 .0 V

0 - 10.0 V

0 - 10.0 V

Monitoring Levels and Accuracy of Full Scale

Output Voltage

Output Current

Remote Analog

Monitoring Accuracy

± 0.50%

± 0.75%

Digital

Monitoring Accuracy

± 0.50%

± 0.75%

Remote Analog

Monitoring Levels

0 - 10.0 V

0 - 10.0 V

Experience you can rely on.

Our products have evolved by listening to our customers and working
with them to find solutions to their problems. Our continual growth is
based upon our innovative engineering, superior manufacturing meth-
ods, and dedicated employees. Today, all engineering and manufactur-
ing is performed in Flemington, NJ.

Output

Ripple

See Model Charts

Line Regulation

Voltage Mode: ± 0.004% of full scale

Current Mode: ± 0.02% of full scale

Load Regulation

Voltage Mode: ± 0.01% of full scale

Current Mode: ± 0.04% of full scale

Load Transient Response

2 ms to recover within ±1% of regulated output, with a

50% to 100% or 100% to 50% step load change

Efficiency

≥ 86% (See Model Charts)

Stability

± 0.10% for 8 hrs. after 30 min. warmup

Isolation

Maximum input voltage to ground: ±2500 VAC

Maximum output voltage to ground: ±1000 VDC

User inputs and outputs: Referenced to earth ground

Maximum Slew Rate

Standard Models:

100 ms for output voltage change from 0 to 63%

100 ms for output voltage change from 0 to 63%

With High Slew Rate Option:

4 ms for output voltage change from 0 to 63%

8 ms for output voltage change from 0 to 63%

Bandwith

Standard Models:

3 Hz with remote analog voltage programming,

2 Hz with remote analog current programming.

With High Slew Rate Option:

90 Hz with remote analog voltage programming,

60 Hz with remote analog current programming.

Analog Output Impedances

Voltage output monitoring: 100 ohm,

Current output monitoring: 100 ohm,

+10V Ref: 1 ohm.

Physical

Power

(kW)

Size (H” x W” x D”)

Rack

Units

Weight

2 kW

4 kW

6 kW

8 kW

3.50 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)

10.25 x 19 x 24 in (26.0 x 48.3 x 61.0 cm)

2U

2U

2U

2U

45 lbs (20.41 kg)

47 lbs (21.32 kg)

48 lbs (21.77 kg)

48 lbs (21.77 kg)

Control Limits

Remote Sense Limits

3% maximum voltage drop from output to load

Digital control inputs

and outputs limits

Input voltage: 0 to 5 V
Output voltage: 0 to 5 V, 5 mA drive capacity

Note: Specifications are subject to change without notice. For three-phase configurations,
specifications are line-to-neutral. Unless otherwise noted, input voltages and currents are
specified for three-phase configurations.