3.3 kW

MODELS

VOLTS

(Vdc)

AMPS

(Adc)

RIPPLE

(mVrms)

6.6 kW

MODELS

VOLTS

(Vdc)

AMPS

(Adc)

RIPPLE

(mVrms)

10 kW

MODELS

VOLTS

(Vdc)

AMPS

(Adc)

RIPPLE

(mVrms)

PQ5-600

PQ8-400

PQ10-300

PQ16-200

PQ20-165

PQ32-100

PQ40-82

PQ50-65

PQ80-41

PQ100-33

PQ125-26

PQ160-20

PQ200-16

PQ250-13

PQ375-8

PQ500-6

PQ600-5

PQ800-4

PQ1000-3

0-5

0-8

0-10

0-16

0-20

0-32

0-40

0-50

0-80

0-100

0-125

0-160

0-200

0-250

0-375

0-500

0-600

0-800

0-1000

0-600

0-400

0-300

0-200

0-165

0-100

0-82

0-65

0-41

0-33

0-26

0-20

0-16

0-13

0-8

0-6

0-5

0-4

0-3

50

40

40

35

40

40

40

50

60

60

100

120

125

130

170

220

250

300

350

PQ8-800

PQ10-600

PQ16-400

PQ20-330

PQ32-200

PQ40-165

PQ50-130

PQ80-82

PQ100-66

PQ125-53

PQ160-41

PQ200-33

PQ250-26

PQ375-17

PQ500-13

PQ600-10

PQ800-8

PQ1000-6

0-8

0-10

0-16

0-20

0-32

0-40

0-50

0-80

0-100

0-125

0-160

0-200

0-250

0-375

0-500

0-600

0-800

0-1000

0-800

0-600

0-400

0-330

0-200

0-165

0-130

0-82

0-66

0-53

0-41

0-33

0-26

0-17

0-13

0-10

0-8

0-6

40

40

35

40

40

40

50

60

60

100

120

125

130

170

220

250

300

350

PQ10-900

PQ16-600

PQ20-500

PQ32-300

PQ40-250

PQ50-200

PQ80-125

PQ100-100

PQ125-80

PQ160-62

PQ200-50

PQ250-40

PQ375-27

PQ500-20

PQ600-16

PQ800-12

PQ1000-10

0-10

0-16

0-20

0-32

0-40

0-50

0-80

0-100

0-125

0-160

0-200

0-250

0-375

0-500

0-600

0-800

0-1000

0-900

0-600

0-500

0-300

0-250

0-200

0-125

0-100

0-80

0-62

0-50

0-40

0-27

0-20

0-16

0-12

0-10

40

35

40

40

40

50

60

60

100

120

125

130

170

220

250

300

350

MODELS AND RATINGS

Notes:

1. Specifications are subject to change without notice

2. Specify optional EMI filter to meet EMC requirements

3. For other options, consult factory

MODEL ORDERING SYSTEM

SERIES

NAME

FRONT

PANEL

VO DC

IO DC

INPUT

VOLTAGE

PQ

TS

MS

MT

A: Analog

D: Digital

C: Com-

puter

See

Tables

See

Tables

240 SP

208

240

380

415

440

480

Example: PQD32-200/208
PQ

D

32

200

240

Options:

Custom output voltage

IEEE-488 Interface

Ethernet Interface

USB Interface

EMI Filter

SPECIFICATIONS:

Input Voltage:

240 Vac, 50-60 Hz, 1φ (3.3 kW only)

208/240 Vac, 50-400 Hz, 3φ

380/415 Vac, 50-400 Hz, 3φ

440/480 Vac, 50-400 Hz, 3φ

Line Regulation:

Voltage Mode: ± .004% of full scale

Current Mode: ± .02% of full scale

Load Regulation:

Voltage Mode: ± .01% of full scale

Current Mode: ± .04% of full scale

Stability: ± 0.10

% for

8 hrs. after 30 min. warmup

Isolation:

Maximum input voltage to ground: ±2500 Vac

Maximum output voltage to ground: ±1000 Vdc

User inputs and outputs: referenced to earth ground

Power Factor: greater than 92% at maximum power.
Ambient Temperature: 0°C to 50°C
Storage Temperature: -25°C to +85°C
Temperature Coeffecient: 0.04/°C of max. output current
Water Cooling:

25°C maximum inlet temperature

1.5 GPM minimum flow rate

80 PSI maximum pressure

1/4” NPT female pipe size

Efficiency:

≥ 86%

Size (H” x W” x D”) and Weight:

3.3 kW Model: 5¼” H x 19” W x 24” D at 74 lbs

6.6 kW Model: 5¼” H x 19” W x 24” D at 97 lbs

10 kW Model: 5¼” H x 19” W x 24” D at 125 lbs

Load Transient Response: 2 ms to recover within ±1% of regulated

output with a 50% to 100% or 100% to 50% step load change
Remote sense limits:

3% maximum voltage drop from output terminals to load

Remote analog programming limits:

Voltage set point: 0-2.0 Vdc

Current set point: 0-2.0 Vdc

Over voltage trip set point: 0 to 2.2 Vdc

Over current trip set point: 0 to 2.2 Vdc

Modulation: 0 to 2.0 Vdc (D Version models only)

Remote analog programming accuracy of full scale:

Voltage set point: ±.50%

Current set point: ±.75%

Over voltage trip set point: ±.50%

Over current trip set point: ±.75%

Analog monitoring accuracy of full scale:

Output voltage: ±.50%

Output current: ±.75%

Digital programming accuracy of full scale:

Voltage set point: ±.50%

Current set point: ±.75%

Over voltage trip set point: ±.50%

Over current trip set point: ±.75%

Digital readback accuracy of full scale:

Output voltage: ±.50%

Output current: ±.75%

Period programming limits:

Minimum period: 10 msec

Maximum period: 9997 sec or 2.77 hours

Digital control inputs and outputs limits:

Input voltage: 0 to 5 Vdc

Output voltages: 0 to 5 Vdc, 5 mA drive capacity per line

5 V supply: 25 mA