Specifications

(From 5% to 100% rated voltage.
All units operate down to zero
output with very slight degradation
of performance.)

Input:

105-125V RMS 48-420 Hz, single

phase, less than 1.5 amperes. Input
connector per IEC 320 with mating line
cord provided.

Efficiency:

Better than 75% at full load.

Output:

Continuous, stable adjustment,

from 0 to rated voltage or current by
panel mounted 10-turn potentiometers
with 0.05% resolution, or by external 0
to 10V signals is provided. Linearity is
<1% of rated. Accuracy is 1% of rated +
1% of setting. Repeatability is <0.1%
of rated.

Stored Energy:

10kV model, 200

millijoules; 50kV model, 1 joule.

Voltage Regulation:

Better than 0.005%

+1mV/mA, line and load.

Ripple:

Better than 0.03% RMS of rated

voltage +0.5V at full load.

Current Regulation:

Better than 0.05%

from short circuit to rated voltage at
any set current condition.

Voltage Monitor:

Zero to +10V DC

signal is equivalent to zero to rated
voltage. Accuracy, 1% of rated voltage.

Current Monitor:

Zero to +10V DC

signal is equivalent to zero to rated
current. Accuracy, 1% of reading
+0.05% of rated current (Reversible
models 1% of reading +0.1% of rated).

Stability:

0.01% per hour, after 1/2 hour

warm-up, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant:

Using either the HV (on/off) or remote
voltage control, with a 75% resistive
load, the output voltage will rise or
decay with a typical time constant of
60 milliseconds (100mS maximum).

Temperature Coefficient:

0.01%

per degree C.

Ambient Temperature:

-20 to +60

degrees C, operating; -40 to +85
degrees C, storage.

Polarity:

Available with either positive,

negative, or reversible polarity with
respect to chassis ground.

Protection:

Automatic current regulation

protects the power supply against all
overload conditions, including arcs and
short circuits. Fuses, surge limiting
resistors, and low energy components
provide the ultimate protection.

Accessories:

Detachable 8 foot shielded

high voltage coaxial cable (see Models
chart for cable type) and 6 foot
detachable line cord are provided.

Designing Solutions for High Voltage Power Supply Applications

GLASSMAN HIGH VOLTAGE INC

.

124 West Main Street, PO Box 317, High Bridge, NJ 08829-0317

(908) 638-3800 • Fax (908) 638-3700 • www.glassmanhv.com

Options

Symbol Description

100

Rated for 90 to 110 volts RMS. 48-420 Hz.

220

Rated for 210 to 250 volts RMS. 48-420 Hz.

CT

Current trip. Power supply trips off when the load current reaches the
programmed level. This option has a rear panel switch that selects either “trip”
operation or current limiting.

DM 3-1/2 digit LCD panel meters.
5VC 0-5 V voltage and current program/monitor.

Models

Positive

Negative

Reversible

Output

Output Output

Polarity Polarity Polarity

Voltage

Current

Cable

EH1P100L

EH1N100L

EH1R100L

0-1kV

0-100mA

RG-59

EH1.5P65L EH1.5N65L

EH1.5R65L

0-l.5kV

0-65mA

RG-59

EH2P50L

EH2N50L

EH2R50L

0-2kV

0-50mA

RG-59

EH3P33L

EH3N33L

EH3R33L

0-3kV

0-33mA

RG-59

EH5P20L

EH5N20L

EH5R20L

0-5kV

0-20mA

RG-59

EH10P10

EH10N10

EH10R10 0-10kV

0-10mA

RG-8U

EH15P6

EH15N6

EH15R6

0-15kV

0-6mA

RG-8U

EH20P5

EH20N5

EH20R5

0-20kV

0-5mA

RG-8U

EH25P4

EH25N4

EH25R4

0-25kV

0-4mA

RG-8U

EH30P3

EH30N3

EH30R3

0-30kV

0-3mA

RG-8U

EH40P2.5

EH40N2.5

EH40R2.5

0-40kV

0-2.5mA

RG-8U

EH50P2

EH50N2

EH50R2

0-50kV

0-2mA

RG-8U

EH60P1.5

EH60N1.5

EH60R1.5

0-60kV

0-1.5mA

RG-8U

Remote Controls:

Common, +10 volt

reference, interlock, current monitor,
current program, voltage monitor,
voltage program, HV enable/disable,
and ground provided on a rear panel
terminal block.

External Interlock:

Open off, close on.

HV Enable/Disable:

0-1.5V off,

2.5-15V on.

Net Weight: 13 lbs.

Advertising