320asx, Power factor rating curves, Input power requirements (47-63 hz) – Atec Pacific-Power-320ASX User Manual

Page 2: Output ratings 320asx, Asx power source specifications (pf = 1.0, v, 25% f.s.), Refer to the adjacent table

Advertising
background image

320ASX

Power Factor Rating Curves

Input Power Requirements (47-63 Hz)

Output Ratings

320ASX

Rated Power (VA)

1

Coupling Mode

Form

2

Output Voltage

3

V

rms

Max

(L-N/L-L)

Current

4

(A

rms

)

Frequency

Range

Input

Power

Unit Height

In/mm/U

Unit Weight

(Lbs/Kg)

2000

Direct

1Ш/2Ш

150/300
150/260

20/12

7/Ш

15-1200
15-1200

47-63Hz

5.25/133/3U

85 Lbs/39 kgs

NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilites of a given model. Consult factory for assistance in determining specific unit
capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or as a three phase. Output voltage range and 1/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor.

ASX Power Source Specifications (PF = 1.0, V

out

> 25% F.S.)

Output

Frequency

Line Regulation

Load Regulation

(Typ. 3 Phase)

Output Distortion

Ripple and Noise

Response Time

Full Power
15-1,200Hz Direct Coupled

0.1% max for a
±10% line change

3Ø direct coupled: 0.25% 15 to 400 Hz.,
0.50% 400 to 1,200 Hz.

0.25% THD

AVG

15 to 200 Hz

1.25% THD

AVG

200 to 1,200 Hz

-66dB

60 µsec typical,
10-90% load step

Input Voltage

Input Current

Recommended

Input service

100V 1Ø

±10%

22A

rms

25A

20A

rms

25A

18A

rms

25A

10A

rms

15A

9A

rms

15A

9A

rms

15A

110V 1Ø

±10%

120V 1Ø

±10%

200/V 1Ø

±10%

230V 1Ø

±10%

240V 1Ø

±10%

208V 1Ø

±10%

10A

rms

15A

M99211 Transformer Option

When combined with the 320ASX

,

the M99211

external Transformer assembly provides an additional

3Ø, high voltage, output range. Three high performance,

multi-tapped, autotransformers are assembled in a 19"

rack-mount chassis and are configured with either a 1.5,

2.0, 2.5:1 step-up ratio (specified at time of order).

Refer to the adjacent table

for rated output voltages

and currents when supplied with a nominal, 125 V/Ø

input signal. Complete M99211 modification description

available on request. Additional current/voltage ranges

available, consult factory.

M99211 Transformer Assembly Rear View

Rated Power (VA) Output Ratio

Nominal Output

Voltage

(L-N/L-L)

Current

A

rms/Ø

Dimensions

Weight

2000

1.5:1
2.0:1
2.5:1

187/325
250/433
312/540

3

2.25

1.8

3U

5.25 x19 x 23

133mm x 483mm x 584mm

70 Lbs

32 Kg

Load Regulation

(Typical)

Varies from 2 to 5% depending on

ratio. Improves to less than 0.1% with

external sense and CSC enabled

Rated Continuous load current as a function of Power Factor and Output Voltage-Nominal Input Line

Advertising