Specifi cations, Specifi cations of the main unit, Specifi cations of the communication interface – Atec Kikusui-PCR500 User Manual

Page 4: Dimensions (units: mm)

Advertising
background image

Specifi cations

Specifi cations of the main unit

Note: “TYP value” indicates a typical value and does not guarantee the performance. "rdng" indicates a reading on the device.

PCR500M

PCR1000M

PCR2000M

Input voltage

Nominal rated input: 100 to 120 V AC/200 to 240 V AC, 50/60 Hz, single phase

Input voltage range: 90 to 132 V AC/180 to 250 V AC (automatically determined when the power

is turned on), 47 to 63 Hz, single phase

Input current

Up to 9 A/4.5 A

Up to 18 A/9 A

Up to 36A/18 A

Input power factor

*

1

0.9 (TYP value)

Effi ciency

At least 70%

Output voltage

1 to 135 V AC/2 to 270 V AC (135 V/270 V range)

1.4 to 190 V DC/2.8 to 380 V DC (135 V/270 V range)

Setting Resolution

0.1 V

Output capacity

AC mode: 500 VA at maximum AC mode: 1000 VA at maximum AC mode: 2000 VA at maximum

DC mode: 400 W at maximum

DC mode: 800 W at maximum

DC mode: 1600 W at maximum

Maximum current

AC mode: 5 A/2.5 A

*

2

AC mode: 10 A/5 A

*

2

AC mode: 20 A/10 A

*

2

DC mode: 4 A/2 A

*

3

DC mode: 8 A/4 A

*

3

DC mode: 16 A/8 A

*

3

Output frequency

Range: 40 to 500 Hz, setting: 0.1 Hz, accuracy: ±2×10

-4

Output waveform distortion ratio 0.5% or less (at 50 V to 135 V/100 V to 270V at load power factor 1)

Accuracy of voltmeter

±(0.5% of rdng + 0.3 V/0.6 V)
(Output voltage greater than 13.5 V/27 V and output frequency 45 Hz to 65 Hz/DC at 23 ± 5°C)

Accuracy of ammeter
(RMS)

±(0.5% of rdng + 0.02 A/0.01 A) ±(0.5% of rdng + 0.04 A/0.02 A) ±(0.5% of rdng + 0.08 A/0.04 A)

(5% to 100% of the maximum output current and output frequency 45 Hz to 65 Hz or DC at 23 ± 5°C)

Dimensions (maximum)

214W × 124 (150)H × 350 (395)D mm 429 (450)W × 128 (150)H × 350 (400)D mm 429 (450)W × 128 (150)H × 450 (500)D mm

Weight

Approximately 6 kg

Approximately 11 kg

Approximately 15 kg

Operating temperature
and humidity range

0 to 40°C, 20%rh to 80%rh (non-condensing)

Storage temperature and
humidity range

-10°C to 60°C, 90%rh or less (non-condensing)

*1 When the output voltage is 100 V/200 V (in the 135 V/270 V range), the current is maximum, and the load power factor is 1.
*2 When the output voltage is 1 V to 100 V/2 V to 200 V. Depends on the power capacity when the output voltage is 100 V to 135 V/200 V to 270 V.
*3 When the output voltage is 1.4 V to 100 V/2.8 V to 200. Depends on the power capacity when the output voltage is 100 V to 190 V/200 V to 380 V.

Specifi cations of the communication interface

RS-232C

Conforms to EIA232D specifi cations. D-SUB9 pin connector.
Baud rate: 1200, 2400, 4800, 9600, 19200 bps
Data length: 8 bits, stop bit: 1 bit, no parity bit, X-Flow contorol

GPIB (IB21: optional)

Conforms to IEEE STD.488.1-1978 specifi cations.
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E1

USB (US21: optional)

Conforms to USB 2.0 specifi cations.
Conforms to USBTMC-USB488 device class specifi cations.
Communication speed: 12 Mbps (full speed)

Common

Software protocol: IEEE 488.2 STD 1992
Command language: SCPI Specifi cation 1999.0

Analog interface specifi cations (EXO4-PCR-M: optional)

Input terminal

Maximum allowable input voltage

±15 V

Type

BNC

Input impedance

10 kΩ ± 5% (not unbalanced)

Isolation voltage

±100 Vmax

EXT-AC mode

*

1

Input voltage range

0 V to ±10 V (DC)

Voltage amplifi cation rate (135 V/270 V range) 13.5 times or 27 times

Frequency setting range

40 Hz to 500 Hz

EXT-DC mode

Input voltage range

ATT off

0 V to ±1.90 Vpeak (0 to 1.35 Vrms sine wave)

ATT on

0 V to ±10 V (DC)

Input frequency range

ATT off

*

2

40 Hz to 500 Hz (sine wave) /40 Hz to 100 Hz (square wave) /DC

Frequency characteristics

ATT off

– 0.3 dB at 500 Hz with respect to 55 Hz (typical value)

Voltage amplifi cation rate
(135 V/270 V range)

ATT off

100 times or 200 times

ATT on

19 times or 38 times

Output voltage distortion ratio

*

3

Main unit specifi cations + 0.5% or less

*1 ATT is always set to on.
*2 Measurable range for voltage, current and power is DC and from 40 Hz to 500 Hz. The frequency is set based on the input waveform cycle.
*3 In the EXT-AC mode, when direct current is input. In the EXT-DC mode, when a sine wave with 0.1% or less distortion rate is input.

Dimensions (units: mm)

Printed in Japan

Issue:Sep.2011 2011091KSOHEC51

MAX 20

124

MAX 150

214

350

MAX 395

MAX 25

MAX 400

350

429

MAX 15

MAX 450

MAX 150

128

PCR500M

PCR1000M

MAX 500

450

MAX 150

128

MAX 450

MAX 15

429

PCR2000M

MAX 30

MAX 30

■ All products contained in this catalogue are equipment and devices that are premised on use under the supervision
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers.

■ Specifi cations,

design and so forth are subject to change without prior notice to improve the quality.

■ Product names and prices are

subject to change and production may be discontinued when necessary.

■ Product names, company names and

brand names contained in this catalogue represent the respective registered trade name or trade mark.

■ Colors,

textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in
printing.

■ Although every effort has been made to provide the information as accurate as possible for this catalogue,

certain details have unavoidably been omitted due to limitations in space.

■ If you fi nd any misprints or errors in this

catalogue, it would be appreciated if you would inform us.

■ Please contact our distributors to confi rm specifi cations,

price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.

■Distributor:

530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A.
Phone : 408-733-3432 Facsimile : 408-733-1814

www.kikusuiamerica.com

1-877-876-2807

www.kikusui.cn

Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai City
Phone : 021-5887-9067 Facsimile : 021-5887-9069

Advertising