Atec Pacific-Power_320AMX User Manual

Page 2

Advertising
background image

320AMX-320AMXT

NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model (maximum power in split phase (Form2) direct
coupled mode is 1.3 kVA). Consult factory for assistance in determining specific unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or 3 phase. Output voltage range and 1/2/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor. Current shown is per phase.

Output Ratings

Thermal and

Power Factor Rating Curves

AMX Power Source Specifications (PF = 1.0, V

out

> 25% F.S.)

Input Power Requirements (47-63 Hz)

320AMX

Rated Power (VA)

1

Coupling Mode

Form

2

Output Voltage

3

V

RMS

Max

(L-N/L-L)

Current

4

(A

RMS

)

Frequency

Range

Input

Power

Unit Height

In/mm/U

Unit Weight

(Lbs/Kg)

2,000

Direct

1Ш/2Ш

135/234

20-5000

47-63Hz

8.75/222/5U

125/56.8

Rated Power (VA)

1

Coupling Mode

Form

2

Output Voltage

3

V

RMS

Max

(L-N/L-L)

Current

4

(A

RMS

)

Frequency

Range

Input

Power

Unit Height

In/mm/U

Unit Weight

(Lbs/Kg)

2,000

Direct

1Ш/2Ш

135/234

18/6

20-5000

47-63Hz

320AMX

8.75/222/5U

Transformer Module

5.25/133/3U

320AMX

125 /56.8

Transformer

Module

125 /56.8

Transformer 1.5:1

Transformer 2.0:1

Transformer 2.5:1

202/350

270/468

338/585

12/4

9/3

7.2/2.4

45-5000

45-5000

45-5000

320AMXT

Full Power

20-5,000 Hz Direct Coupled

45-5,000 Hz Transformer Coupled

Output Frequency

Line Regulation

0.1% max for a

±10% line

change

Load Regulation

Direct Coupled Ranges:

0.25% 20 to 2,000 Hz.

0.50% 2,000 to 5,000 Hz.

Improves to less than 0.03% with external sense and CSC enabled.

Transformer Coupled Ranges:

1:5:1 2%
2:0:1 4%
2:5:1 5%

Improve to < 0.1% with external sense and CSC enabled.

Output Distortion

0.1% THD

AVG

45 to 1,000 Hz

0.25% THD

AVG

20 to 5,000 Hz

Ripple and Noise

-72dB

Response Time

5 µsec typ. For

step load change.

Small signal

bandwidth = 5 Hz

to 40 KHz

Input Voltage

Input Current

Recommended

Input service

208VAC 3ØΔ

±10%

11A

RMS

20A

10A

RMS

20A

9A

RMS

20A

6A

RMS

10A

5A

RMS

10A

5A

RMS

10A

220VAC 3ØΔ

±10%

240VAC 3ØΔ

±10%

220/380VAC

±10%

240/416VAC

±10%

277/480VAC

±10%

(Cost Option)

18/6

OUTPUT VOLTAGE-AC VOLTS RMS

Short term overloads to 150% are permitted. Operating time

before thermal shutdown or circuit breaker trip varies from

seconds to several minutes depending upon line and tempera-

ture conditions.

THERMAL RATING -AC CURRENT RMS

Short tem overloads to 150% of rated current are permitted.
Operating time before thermal shutdown or circuit breaker trip
varies from seconds to several minutes depending upon line

and temperature conditions.

Rated Continuous Load Current as a Function of Ambient Temperature and Power Factor and Output Voltage at Nominal Input Line.

135/270

6/Ш

1Ш/2Ш

1Ш/2Ш

1Ш/2Ш

135/270

202/404

270/540

338/600

4/Ш

3/Ш

2.4/Ш

6/Ш

Advertising