Plz-3w/3wh series, Electronic load (cc·cr·cv·cp), Specifications(plz-3wh series) – Atec Kikusui-PLZ1003W User Manual

Page 7

Advertising
background image

Copyright © 2001 KIKUSUI ELECTRONICS CORP. All rights reserved.

http://www.kikusui.co.jp/

Page7

PLZ-3W/3WH series

ELECTRONIC LOAD (CC·CR·CV·CP)

Specifications(PLZ-3WH series)

Operating Area

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Operating voltage

(DC)*1

5 to 500 V

Current

7.5 A

15 A

30 A

50 A

Power

150 W

300 W

600 W

1000 W

Minimum operation-

starting voltage*2

1 V

*1 Current can flow in a range of 1 to 5 V. However, the specifications for this instru

ment may not be met.

*2 Minimum voltage at which current starts to flow in the instrument

Constant Voltage Mode

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Operating range (DC)

5 V to 500 V

Setting accuracy*1

±

0.1% of rated voltage

Setting resolution

125 mV

DC input current

regulation*2

±

0.01% of rated voltage

Temperature coefficient

±

100 ppm/

°

C of rated voltage (typical value)

*1 In a range of 23

±

5

°

C (with the load terminals remote sensed)

*2 With respect to an input current change of 10% to 100% of the rated current at 5 V

input voltage (with the load terminals remote sensed)

Constant Power Mode

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Operating range

15 to 150 W

30 to 300 W

60 to 600 W

100 to 1000 W

Setting accuracy*1

±

2% of rated power

Setting resolution

0.025% of rated power

DC input voltage regulation*2

2% of rated power

Ripple current*3

Complies with graph 2 (typical values)

Temperature coefficient

±

1000 ppm/

°

C of rated power (typical value)

*1 In a range of 23

±

5

°

C and at 20 V input voltage (with the load terminals remote sensed)

*2 With respect to an input voltage change of 20 V to 500 V at rated power (with the load

terminals remote sensed)

*3 When the ripple noise of input voltage is 5 mV or less

Constant Resistance Mode

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Operating range

Range H*5

1.6

to 20k

0.8

to 10k

0.4

to 5k

0.24

to 3k

0.625 to

1.25 to

2.5 to

4.17 to

5

×

10

-5

S

10

-4

S

10

-4

S

3.3×

10

-4

S

Range L*5

16

to 200k

8

to 100k

4

to 50k

2.4

to 30k

0.0625 to

0.125 to

0.25 to

0.417 to

10

-6

S

10

-5

S

10

-5

S

3.3×

10

-5

S

Setting resolution

Range H*6

0.156 mS

0.3125 mS

0.625 mS

1 mS

Range L*6

0.0156 mS

0.03125 mS

0.0625 mS

0.1 mS

Setting accuracy

(current conversion)*1

±

(1% of rated current +a)*3

Stability

DC input voltage regulation*2

6%

Temperature

±

(1000 ppm/

°

C + 4 m

/

°

C)

coefficient

at minimum resistance value

Ripple noise*4

Complies with graph 1 (typical values)

*1 In a range of 23

±

5

°

C and at 12 V input voltage

*2 With respect to an input voltage change of 5 V to 12 V at the minimum resistance

value. For other resistance, the voltage variations will be within 6% of the maximum

conductance (S) value of the setting range with respect to variations in allinput

voltages. (with the load terminals remote sensed)

*3

α

= 12 V

÷

set resistance - 12 V

÷

(set resistance + 120 m

)

*4 A repetitive noise of about 155 kHz may be superimposed on input current.

*5 S:siemens

*6 mS: millisiemens

Note: Conductance (S) x input voltage (V) = load current (A)

Conductance (S) = 1/resistance (

)

Constant Current Mode

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Operating range

Range H

0 to 7.5 A

0 to 15 A

0 to 30 A

0 to 50 A

Range L

0 to 0.75 A

0 to 1.5 A

0 to 3 A

0 to 5 A

Setting accuracy

(with respect to rated

±

(0.3%

±

(0.3%

±

(0.3%

±

(0.3%

current)*1

+ 7.5 mA)

+ 15 mA)

+ 30 mA)

+ 50 mA)

Setting resolution

Range H

2 mA

4 mA

8 mA

13 mA

Range L

0.2 mA

0.4 mA

0.8 mA

1.3 mA

Stability

Line regulation*2

3 mA

DC input voltage regulation*3

20 mA

Temperature coefficient

±

100 ppm/

°

C of rated current (typical value)

Ripple noise*4

RMS*5

2 mA

2 mA

3 mA

5 mA

Measuring current*6

At 7.5 A

At 15 A

At 30 A

At 50 A

Peak-to-peak

20 mA

20 mA

30 mA

50 mA

Measuring current

At 7.5 A

At 15 A

At 30 A

At 50 A

*1 In a range of 23

±

5

°

C

*2 With respect to a variation of

±

10% of the center value of the input supply voltage at

the rated current of 20 V input voltage

*3 Value obtained when input voltage is varied from 5 V to 500 V at the current of rated

power/500 V

*4 At the rated current of 20 V input voltage

*5 5 Hz to 500 kHz

*6 DC to 15 MHz

Tr/Tf, Switching and Soft-start Operations, Remote Sensing, and Protective Features

PLZ153WH

PLZ303WH

PLZ603WH

PLZ1003WH

Tr/Tf setting*1

Operation mode

Constant current

Setting range

50, 100, 200, 500

µ

s

1, 2, 5, 10 ms

Setting accuracy*2

±

30% of set value,

±

15

µ

s

Switching operation

Operation mode

Constant current, constant resistance

Time setting range

1 to 5000 ms

Time setting accuracy

±

5% of set value

Soft-start operation

Operation mode

Constant current(C.C)

Setting range

0.5, 1, 2, 5, 10, 20, 50, 100 ms

Setting accuracy

±

30% of set value,

±

100

µ

s

Remote sensing

Sensing voltage

5 V*3

Protective features

Over current protection

Limit is activated at about

(OCP)

+5% of rated current.

Overheat protection

Load current is cut off at a he

(OHP)

at sink temperature of about 105

°

C.

Reverse connection

protection

With diodes and fuses

Power transistor

protection

With fuses

Overvoltage protection

(OVP)

Load switch will be turned off.

*1 Within an input voltage range of 12 V to 500 V.

Rise time (Tr) and fall time (Tf) are times required to reach 10% to 90% of current

waveform.

*2 Tr/Tf setting is valid when the changes in load current fall within a range of 2% to

100% of the rated current value.

*3 2.5 V at one terminal

Advertising