XHR Series : Product Specifications

XHR 1 kW Internal Interface Specifications with RS-232 or GPIB Interface Installed

1, 8

Model

Program Accuracy

Readback Accuracy

Voltage

(mV)

Current

(mA)

OVP

(mV)

Voltage

Current

XHR 7.5-130

10 +0.12%

900 +0.1%

80

30 +0.12%

900 +0.1%

XHR 20-50

50 +0.12%

750 +0.1%

200

60 +0.12%

750 +0.1%

XHR 33-33

75 +0.12%

500 +0.1%

330

75 +0.12%

500 +0.1%

XHR 40-25

75 +0.3%

350 +0.15%

400

75 +0.3%

350 +0.1%

XHR 60-18

150 +0.25%

250 +0.1%

600

150 +0.25%

250 +0.1%

XHR 100-10

150 +0.35%

140 +0.15%

800

150 +0.35%

140 +0.15%

XHR 150-7

225 +0.35%

120 +0.1%

1500

225 +0.35%

120 +0.1%

XHR 300-3.5

225 +0.35%

80 +0.1%

3000

225 +0.35%

80 +0.1%

XHR 600-1.7

250 +0.35%

80 +0.1%

6000

300 +0.35%

80 +0.1%

Model

Temperature Coefficient

5

Maximum Remote

Sense

Line Drop Compensation

6

OVP Adjustment

Range

(5%to 110% of Vmax)

Efficiency

7

Voltage

(0.02% of Vmax/°C)

Current

(0.03% of Imax/°C)

XHR 7.5-130

1.5 mV

39 mA

3 V / line

0.375-8.25 V

81%

XHR 20-50

4 mV

15 mA

5 V / line

1-22 V

83%

XHR 33-33

6.6 mV

9.9 mA

5 V / line

1.65-36.3 V

83%

XHR 40-25

8 mV

7.5 mA

5 V / line

2-44 V

83%

XHR 60-18

12 mV

5.4 mA

5 V / line

3-66 V

84%

XHR 100-10

20 mV

3 mA

5 V / line

5-110 V

84%

XHR 150-7

30 mV

2.1 mA

5 V / line

7.5-165 V

85%

XHR 300-3.5

60 mV

1.1 mA

5 V / line

15-330 V

85%

XHR 600-1.7

120 mV

0.48 mA

5 V / line

30-660 V

85%

Specifications subject to change without notice.
1. Specifications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Line drop is subtracted from total voltage available at supply output.
7. Typical efficiency at 115 Vac input and rated output power.
8. Apply accuracy specifications according to the following voltage program accuracy example:

Set a model 20-50 power supply to 10 V. The expected result will be within the range of
10 V ± 75 mV ± 0.12% of the set voltage of 10 V.