150 kw sg series : product specifications – Atec Sorensen-SG Series User Manual

Page 3

Advertising
background image

858.458.0223

[email protected]

Output: Voltage and Current Ranges

3U

6U

Ripple & Noise

Power

4/5 kW

8/10 kW

12/15 kW

16/20 kW

20/25 kW

24/30 kW

rms

(20 Hz-300 kHz)

p-p

(20 Hz-20 MHz)

Voltage

Current

10

400

800

1200

1600*

2000*

2400*

20 mV

50 mV

15

267

534

801

1068*

1335*

1602*

20 mV

50 mV

20

250

500

750

1000*

1250*

1500*

20 mV

60 mV

30

167

334

501

668*

835*

1002*

20 mV

60 mV

40

125

250

375

500*

625*

750*

20 mV

75 mV

50

100

200

300

400*

500*

600*

20 mV

75 mV

60

83

167

250

333

417

500

20 mV

75 mV

80

63

125

188

250

313

375

20 mV

100 mV

100

50

100

150

200

250

300

20 mV

100 mV

160

31

63

94

125

156

188

25 mV

150 mV

200

25

50

75

100

125

150

25 mV

175 mV

250

20

40

60

80

100

120

30 mV

200 mV

330

15

30

45

61

76

91

30 mV

200 mV

400

12

25

38

50

63

75

40 mV

300 mV

600

8

17

25

33

42

50

60 mV

350 mV

800

6.2

12.5

18.7

25*

31.2*

37.5*

80 mV

500 mV

1000

5

10

15

20*

25*

30*

100 mV

650 mV

* By way of paralleling 3U supplies

Output

Ripple & Noise (Voltage Mode, Typical)

See Output: Voltage & Current Ranges Chart below. Ripple and noise specified at full load, nominal AC input. Noise measured with 6

ft. cable, 1μf at load

Ripple (Current Mode)

<+/- 0.04% of full scale rms current

Output Voltage Rise Time (40-1000V)

≈< 100 ms 10-90% of full scale typical - full resistive load (Contact factory for model specific slew rates)

Output Voltage Rise Time (10-30V)

Rise Time, ms, max

Condition

10

Measured from 10% to 90% of the output voltage change - resistive load, typical

Output Voltage Fall Time (10-30V)

Fall Time, ms max

Condition

No Load 1

100% CC Load

100% CR Load

Measured from 90% to 10% of the output voltage change. - resistive

load, typical

50

10

10

Output Current Rise Time (10-30V)

Rise Time, ms max

Condition

20

Measured from 10% to 90% of the output current change - resistive load, typical

Output Current Fall Time (10-30V)

Fall Time, ms max

Condition

10

Measured from 90% to 10% of the output current change - resistive load, typical

DC Current Slew Rate

45A / ms typical - resistive load

Line Regulation ( with sense wires used )

(±10% of nominal AC input, constant load)

Voltage Mode: +/- 0.01% of full scale (40-800V)
Current Mode: +/- 0.05% of full scale (40-800V)
Voltage Mode and Current Mode: +/- 0.05% of full scale (10-30V)

Load Regulation (with sense wires used)

(no load to full load, nominal AC input)

Voltage Mode: +/- 0.02% of full scale (40-800V)
Current Mode: +/- 0.1% of full scale
Voltage Mode: +/- 0.05% of full scale (10-30V)

Load Transient Response

Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change

Efficiency

87% typical at nominal line and max load

Stability

±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature, typical

Temperature Coefficient

0.02%/ C of maximum output voltage rating for voltage set point, typical
0.03%/ C of maximum output current rating for current set point, typical

Output Float Voltage

Negative terminal within +/- 300 V of chassis potential. ( We recommend the use of optional isolated analog Interface (IAI). )

Supplies in “series” have a system current limit of the lowest current supply in the system.

4-150 kW

SG Series : Product Specifications

79