Xdl series – Atec Xantrex-XDL Series User Manual

Page 2

Advertising
background image

XDL Series

105 to 215 W Programmable Linear DC Power Supply

Models 35-5 35-5T

35-5P

35-5TP

56-4

56-4P

Output Ranges: Range 1 0-35 V, 0-3A 0-35V, 0-3A

0-35V, 0-3A 0-35V, 0-3A 0-56V, 0-2A 0-56V, 0-2A

Range 2 0-15V, 0-5 A 0-15V, 0-5A

0-15V, 0-5A 0-15V, 0-5A 0-25V,0-4A 0-25V, 0-4A

Range 3 0-35V,0-500.0 mA 0-35V,0-500.0 mA 0-35V,0-500.0 mA 0-35V,0-500.0 mA 0-56V,0-500.0 mA 0-56V,0-500.0 mA

Outputs 1 3

1

3 1 1

Output Power 105 W 215 W

105 W

215 W

112 W

112 W

Interface (GPIB/RS-232/USB) No No

Yes

Yes

No

Yes

Voltage Setting By fl oating point numeric entry or rotary jog wheel; resolution 1mV
Current Setting By fl oating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range
Setting Accuracy Voltage - 0.03% ± 5 mV. Current 0.2% ± 5mA, 0.5mA
Output mode Operation in constant voltage or constant current modes with automatic cross-over and mode indication by LEDs.
DC Output Switch Sets output voltage and current levels to zero when Off.
Output Terminals 4mm terminals on 19mm (0.75”) spacing
Load Regulation Voltage: <0.01% + 2mV Current: <0.01% + 250µA; <0.01% + 50µA on 500mA range (measured at output terminals using remote sense)
Line Regulation Voltage: <0.01% + 2mV for 10% line change Current: <0.01% + 250µA; <0.01% + 50µA on 500mA range
Ripple and Noise Typically <0.35%Vrms 2mVp-p CV mode, and <0.2mArms, <20µArms (500 mA range) CI mode
Transient Response 50µs to within 15mV of set level for a change in load current from full load to half load or vice versa

Temperature Coeffcient <±(50ppm+0.5mV)/ °C (voltage)
Remote Sense Eliminates up to 0.5V drop per lead. Remote sense operation selected from front panel and indicated by LED
Sense Terminals Recessed sprung sockets for direct insertion of wires. Duplicated on rear terminal block (P versions only)

Electrical Specifi cations

Operational AC Input Voltage 115V or 230V ± 10% (adjustable internally, option HV for factory set 230 VAC input), 50/60 Hz. Installation Category II
Operating Temperature Range 5 °C to 40 °C, 20% to 80% RH
Storage Temperature Range -40 °C to 70 °C
Dimensions (HxWxD) 6.3 x 5.5 x 11.4”/160 x 140 x 290 mm (XDL 35-5, XDL 35-5P, XDL 56-4, XDL 56-4P),

6.3 x 11.0 x 11.4”/160 x 280 x 290 mm (XDL 35-5T, XDL 35-5TP)

Weight 11.9 lb/5.4 kg (XDL 35-5, XDL 56-4), 12.1 lb/5.5 kg (XDL 35-5P, XDL 56-4P),

23.1 lb/10.5 kg (XDL 35-5T), 23.3 lb/10.6 kg (XDL 35-5TP)

Benchtop Operation Folding legs are incorporated that can be used to angle the front panel upwards when required
Rack Mount Operation 19 inch 4U mount for up to three single output units or one triple plus one single

Blanking plates available for un-used sections

Warranty 3 years
Approvals CE-marked units meet: EN61010-1 and EN61326

General Specifi cations

1

Output Protection Output will withstand forward voltages of up to 2OV above rated out-

put voltage. Reverse protection by diode clamp for current upto 3A

Fault Condition Trip The output will be shut down if any of the four trip conditions

listed below occur. In addtion to the output being set Off, an

isolated rear panel signal is also activated.

Over Voltage (OVP) Settable 1V to 40V (XDL 35-5) or 62V (XDL 56-4) in 0.1V steps
Over Current (OCP) Settable 0.1A to 5.5A (XDL 35-5) or 4,4A (XDL 56-4) in 0.01A steps

Over Temperature Monitors internal temperature rise to protect against excess

ambient temperature or blocked ventilation slots.

Sense Error

Monitors the voltage between the remote sense terminals and

output terminals to protect against mis-wiring

Trip Output Signal Isolated open-collector output signal on rear panel
Meter Resolution and Accuracy

Voltage (CI mode): Resolution 10mV

Accuracy ± (0.1% of reading + 10mV)

Current (CV mode): Resolution 0.001A; 0.1A on 500mA range

Accuracy ± (0.2% + 0.005A); ± (0.2% + 0.5mA) on 500mA range

V x A:

Resolution 0.01W; 0.001W on 500mA range

Accuracy ± (0.3% + 0.05W); ± (0.3% + 0.005W) on 500mA range

Output Protection and Metering

Output Voltage Switchable 2.7V, 3.3V or 5.0V. Accuracy better than ± 5%
Output Current

>1.0A maximum. LED indication of over-current.

DC Ouput Switch

Sets output voltage level to zero when Off.

Output Terminals

4mm terminals on 19mm (0.75”) spacing. Duplicate terminals at

rear (P versions only)

Output Protection Output will withstand up to 16 V forward voltage. Diode clamped

for reverse voltages and 3 Amps reverse current.

Load Regulation

<1% for 90% load change

Line Regulation

<0.1% for 10% line change

Auxiliary Output-XDL 35-5T and TP

GPIB Conforming with IEEE-488.1 and IEEE-488.2 (N.B. All three

interfaces incorporate full control, readback and status reporting)

BUS Type Selection From front panel (GPIB/RS232/USB)
Address Selection From front panel (1 to 31)
Baud Selection

RS-232 only. From front panel (600 to 19200 baud)

Setting Resolution Voltage - 1mV, Current 0.1mA (0.1 mA on 500 mA range)
Accuracy

See specifi cations under Outputs and Metering

Remote Control Response Time

Interface

Typically <80 ms

Output Voltage Response time varies with range and load conditions. Typical time

to settle to within 1% of the total excursion on a 35V/3A range with

full load is <25ms. With no load it is <7 ms for an upward charge

and <600ms for downward.

Bus Interfaces (P Suffi x versions)

USB Standard USB hardware connection Supplied with device

driver for Win 98 or above. Operates as a virtual COM port.

RS-232 Variable baud rate 19,200 max. Single instrument or Addressable

RS232

Note: Specifications are subject to change without notice.

Store/Recall Settings

Number of Stores 10 (30 total on XDL 35-5T) plus power-down store

Memory Type

Non-volatile using EEPROM

Parameters Stored Range, Set volts, Set current, OVP, OCP

Recall System

Settings are previewed onto the displays before being actioned

1

General Specifi cations apply for 5 to 40°C temperature range. Accuracy specifi cations apply for 18 to 28°C
temperature range after 1 hour warm-up with no load and calibration at 23°C. Typical specifi cations are
determined by design and not guaranteed.

Advertising