DVB-T Measurement Receiver

RFM210

Flexible Configuration

DVB-T transmission systems throughout the

world use a variety of modulation parameters.

The RFM210 has the flexible tuning/demodula-

tion capability needed to handle this variety.

The tuner/demodulator can handle any stan-

dard VHF, UHF or baseband input, implements

both 2K and 8K carrier mode options, and

supports all DVB modulation options, guard

intervals and FEC rates. Options available for

6, 7 or 8 MHz bandwidths.

Multi-layer Monitoring

Broadcasters can use the RFM210 in combi-

nation with other Tektronix monitoring prod-

ucts to form a multi-layer confidence monitor-

ing solution for DVB-T transmission systems.

The RFM210 demodulates the COFDM signal

into either SPI or ASI transport stream for-

mats. These outputs can go directly into MPEG

protocol monitors, offering an easy, space effi-

cient and low cost multi-layer monitoring solu-

tion. Multi-layer monitoring can help quickly

determine if quality and reliability problems in

the transmitted signal came from problems

in the RF modulation/ transmission path or

the MPEG encoding and multiplexing path in

the broadcast system.

Network Capability

Broadcasters can remotely access and control

the RFM210 through a network connection

using SNMP network protocols. RFM210s

installed in remote, and potentially unstaffed,

transmitter sites can also use SNMP to report

alarm conditions through a network connec-

tion. Broadcasters can use the RFM210 net-

work capabilities to monitor multiple transmit-

ter sites from a single, central location.

Space Efficient

At most transmitter facilities, space is at

a premium. The rackmountable, 1RU-high

RFM210 gives broadcasters comprehensive

RF monitoring without consuming large

amounts of rack space.

Characteristics

Product Specifications

Tuner Characteristics

Frequency Range – VHF/UHF 46 to 860 MHz.

Channel Bandwidth – 6/7/8 MHz (Options).

Input Range – –10 to –77 dBm (Optimum –55
to –30 dBm), typical.

Input Impedance – 75

.

Demodulator Characteristics

Modulation Systems – QSPK, 16 QAM, 64 QAM.

Carriers Supported – 2K/8K DVB (T) selectable FFT
automatically selected.

Viterbi FEC – Supports all DVB code rates: 1/2, 2/3,
3/4, 5/6, and 7/8.

Guard Intervals – Supports all DVB guard intervals:
1/32, 1/16, 1/8, and 1/4.

Hierarchical Modes – Both HP and LP streams
available simultaneously.

Error Correction – Reed Solomon (204, 188)
and Viterbi.

Synchronization Monitoring – Status of TPS, FEC
decoder, etc.

Measurements

BER – Bit Error Ratio pre/post Viterbi and post RS.

MER – Modulation Error Ratio in dB, Average MER in
%, Peak MER in %.

S/N – Signal to Noise ratio in dB.

STE – System Target Error, Mean and Deviation.

AI – Amplitude Imbalance in %.

QE – Quadrature Error in °.

CS – Carrier Suppression in dB.

PJ – Phase Jitter in °

RMS

.

SF – Sync Failure.

UCE – Uncorrectable Error Blocks.

ENM – Estimated Noise Margin, auto calculated
in dB.

TR 101 290 – Full analysis including Amplitude,
Group Delay and Impulse Response.

RF Measurement Receivers •

www.tektronix.com/video_audio

2