Command line format: COMMAND<parameter1><parameter2>…[CR]
Current value will have one decimal place for models 1687B and 1688B, and two
decimal places for Model 1685B.
Command code &

Return value

Function

Example

Input command:

VOLT{<voltage>}[CR]

Return value:

OK[CR]

Set voltage level

<voltage> = 000-XXX

Input command:

VOLT010[CR]

Return value:

OK[CR]

Sets voltage level to 1.0 V

Input command:

CURR{<current>}[CR]

Return value:

OK[CR]

Set current level

<current> = 000-XXX

Input command:

CURR025[CR]

Return value:

OK[CR]

Sets current level to 2.5 A

Input command:

PROM{<preset 1

voltage>}{<preset 1

current>}{<preset 2

voltage>}{<preset 2

current>}{<preset 3

voltage>}{<preset 3

current>}[CR]

Return value:

OK[CR]

Set power supply

preset memory values

<preset X voltage> =

000-XXX

<preset X current> =

000-XXX

Input command:

PROM011022033044055066

Return value:

OK[CR]

Sets preset 1 voltage and current

to 1.1 V and 2.2 A, preset 2

voltage and current to 3.3 V and

4.4 A, and preset 3 voltage and

current to 5.5 V and 6.6 A

Input command:

GETS[CR]

Return value:

[voltage][current][CR]

OK[CR]

Get voltage and

current setting values

from power supply

[voltage] = 000-XXX

[current] = 000-XXX

Input command:

GETS[CR]

Return value:

025051

OK

Indicates voltage setting is 2.5 V

and current setting is 5.1 A