B&K Precision 1730A - Manual User Manual

Page 8

Advertising
background image

7

Model 1730A

Model 1710A

METERING

Voltmeter
Range
Accuracy

Ammeter
High Range
Low Range
Accuracy



0 to 32V
±2.5%


0 to 3.2A
0 to 0.53A
±2.5%



0 to 32V
±2.5%


0 to 1.04A
0 to 0.26A
±2.5%

POWER REQUIREMENTS

Domestic: 120 VAC ±10%, 60 Hz
International: 120, 220, 230, 240 VAC ±10%, 50/60 Hz

POWER CONSUMPTION

Approx. 180W or less at full load

Approx. 70W or less at full load

PROTECTION

Reverse polarity protection,
Current limiting

Reverse polarity protection,
Current limiting

TEMPERATURE RANGE

Operation
Storage


0° to +40° C, <75% R.H.
-15° to +70°C, <85% R.H.


0° to +40° C, <75% R.H.
-15° to +70°C, <85% R.H.

DIMENSIONS (HxWxD)

6.2 x 5.5 x 12.5"

6.2 x 5.5 x 12.5"

WEIGHT

10.5 lb.

8 lb.

ACCESSORIES SUPPLIED

Spare Fuse
Instruction Manual

Spare Fuse
Instruction Manual



NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product
information.