8 Specifications

1737

Output Ratings ( 0 °C~40 °C)
Voltage

0-60 V

Current

0-3 A (0-30 V),

0-2 A (30-60 V)

Load Regulation ±(% of output+offset)
Voltage

0.01% + 3 mV

Current

0.2% + 3 mA

Line Regulation ±(% of output+offset)
Voltage

0.01% + 3 mV

Current

0.2% + 3 mA

Ripple & Noise (20 Hz ~ 20 MHz)
Voltage

1 mVrms

Current

≤ 3 mArms

Recovery Time

≤ 100

μs

Meter Resolution
Voltage

10 mV

Current

1 mA

Metering Accuracy
Voltage

0.5% + 9 digits

Current

0.5% + 9 digits

General
Power Requirements

120/220 VAC ±10%, 50/60 Hz

Power Consumption

≤ 180 W

Protection

Reverse polarity, current limiting

Operating Environment
Temperature

32 °F to 104 °F (0 °C to 40 °C)

Humidity

75% R.H.

Temperature coefficient (0 °C~35 °C)

±(%of output+offset)

300 ppm/°C

Storage Temperature

5 °F to 158 °F (-15° to +70° C)

Advertising