5. Specifications
INSULATION
Test Voltage
250Vdc
500Vdc
1000Vdc
+10%-0%
+10%-0%
+10%-0%
Mirror scale
100MW
200MW
400MW
Mid Scale
1MW
2MW
4MW
Scale Multiplier
x1/2
x1
x2
Accuracy
±3%
Output Short-Circuit Current
1.3mA
Regulated Output Voltage (up to 1mA current)
263.5V / 525V / 1052V
CONTINUITY
Low W
0 - 3W
0 - 500
W
Test Leads / Fuse Zero W Adjustment by knob
Output Short-Circuit Current
205mA
Accuracy
±1.5% of scale length
AC Voltage
Range
0 - 600Vac
Accuracy
±3% of scale length
Voltage Warning
Warning Light Circuit Live lit from 90Vdc / 70Vac
Buzzer Beep from 24Vac / dc
Battery Check
Battery Check indicate good batteries from 8Vdc to 13Vdc
during a Load test of 205mA.
Battery OK
Battery OK Led lit from 8Vdc and is operative while testing.