Safety instructions – KOSPEL SW Termo Max User Manual

Page 20

Advertising
background image

20

Safety instructions

1. Read and strictly follow this installation and operating instructions to ensure a

long life and reliable cylinder operation.

2. The manufacturer of this cylinder will not be liable for any damages due to the

failure to follow the installation and operation instructions.

3. The cylinder must not be installed in rooms where the temperature may drop

below 0

0

C.

4. The cylinder installation and initial start-up as well as all electrical and hydraulic

work must be performed by a qualified professional installer.

5. The cylinder is designed for vertical installation only (screw on feet).

6. The cylinder must be mounted in the place and in such a way to avoid room

flooding caused be leaking tank or connectors.

7. Connections to the water, central heating and solar system pipes must be made

in accordance with diagram in this installation instruction. Failure to observe the

installation instruction invalidate the warranty and may cause cylinder damage.

8. A connection to water supply system must be made in accordance with the legally

binding standards.

9. The cylinder is a pressure appliance designed for connection to the water supply

system where the water pressure doesn’t exceed 0,6 MPa. If the water pressure

exceeds 0,6 MPa the pressure reducing valve before cylinder must be fitted.

10. A small leak from the safety valve through the outlet pipe may occur, it is a normal

operating state of the appliance. The outlet of the pipe has to remain opened. Do

not clog it, as a clogged outlet may cause a break down of the cylinder.

11. Do not use the cylinder if you suspect that the safety valve may be faulty.

12. The tank is equipped with a magnesium anode - an additional protection against

corrosion. The anode is an operating part therefore it is exposed to wear.

The condition of the magnesium anode should be controlled every 12

months. The anode must be replaced once every 18 months.

13. Rated temperature of water in the cylinder should not exceed 80

0

C.

The cylinder is suitable for fitting an immersion heater with thermostat e.g. GRBT 1.4,

GRBT 2.0. The immersion heater must be fitted in lieu of cork 1½.

A maximum length of immersion heater:

-

360 mm (Cylinders of 100,120,140 litres)

-

450 mm (Cylinders of 200 litres)

-

550 mm (Cylinders of 250,300 litres)

-

600 mm (Cylinders of 400 litres)

Advertising
This manual is related to the following products: