Reliability test, 15min 30min, Bdt-3108 lf – BeStar BDT-3108 LF User Manual
Page 4: Transducer

C
C
Drawn
A
Rev.
6
Date
A
B
Approved by:
Checked by:
Note
5
4
Date:
Drawn by:
3
2
A
Page:4 of 5
1
B
T
h
is
p
ri
n
t
and
i
n
fo
rm
a
ti
on
t
he
re
i
n
a
re
p
rop
ri
e
ta
ry
t
o
B
e
s
ta
r E
le
c
tr
on
ics
I
ndu
s
tr
y
C
o
.,
L
td.
and
s
ha
ll
no
t
be
u
s
ed
i
n
w
ho
le
o
r
in
p
a
rt
w
it
hou
t
it
s
wr
itt
en
c
on
tent
D
E
F
G
H
6
5
4
3
2
D
E
F
G
1
H
B
BDT-3108 LF
06/09/04
高 正
DRG NO:BS/TET01.138B
06/09/04
01/06/05
程久生
郭 敏
Transducer
高 正
王善梅
BDT-3108 LF
4.1 high temperature test
Temperature +60 C
Duration 96hrs
4.2 low temperature test
Temperature -20 C
Duration 96hrs
4.3 Life test in normal temperature
Power supply Rated voltage
Duration 1000hrs
4.4 temperature cycle test
Cycles 5
4.5 Humidity cycle test
Cycles 5
4.6 Drop test
Height 70cm
(to 10mm thickness woodenboard)
Direction 3
Notice: All specification must be satisfied in this condition.
15min
10h
All these tests above should be measured after leaving normal temperature for 2hrs.
25 C90-95% RH
-20 C
30min
1h
1h
12h
65 C90-95% RH
15min
30min
4.Reliability Test
+20 C
+20 C
+60 C