Bray 52 Series User Manual

Page 4

Advertising
background image

BRAY Series 52 Valve Status Monitor

Operation and Maintenance Manual

2

CAT 3, S52 2N1ProxSensor

Valve Status Monitor

User Instructions. (EHSR 1.0.6)

specific to hazardous area installations

(reference European ATEX Directive 94/9/EC,

Annex II, 1.0.6.)

The following instructions apply to the Bray

International S52 2N1ProxSensor Valve Status

Monitors Part nos. 52100*-71114536 (*= 1, 2, 4,

6, 7, 8, and 9) covered by certificate number Sira

11ATEX4135X. Translations into other languages

are available on request.

1. The equipment may be used with flammable

gases and vapours with apparatus Gas Groups

IIA, IIB and IIC in Zone 2 locations, and Dust

Group IIIB in zone 22 locations.

2. The equipment Temperature Class is T4 for

gases and T102°C for dusts, and is only certified

for use in ambient temperatures in the range

-20°C to +70°C and should not be used outside

this range.

3. Installation shall be carried out in accordance

with the applicable code of practice by suitably-

trained personnel.

4. Repair of this equipment shall be carried out in

accordance with the applicable code of practice.

5. The X suffix to the certificate number is to

indicate that there is a special condition for safe

use, which is regarding the potential build up of

static electricity and the precautions to be taken,

some of the sensors must be protected from

impact/ mechanical damage.

6. If the equipment is likely to come into contact

with aggressive substances, then it is the

responsibility of the user to take suitable

precautions that prevent it from being adversely

affected, thus ensuring that the type of protection

is not compromised.

Aggressive substances - e.g. acidic liquids or gases

that may attack metals, or solvents that may affect

polymeric materials.
Suitable precautions - e.g. regular checks as part

of routine inspections or establishing from the

material’s data sheet that it is resistant to specific

chemicals.

Copy of Certificate number Sira 11ATEX4135X

S52 2N1ProxSensor Intrinsically

Safe Valve Status Monitor

User Instructions

specific to hazardous area installations

(reference European ATEX Directive 94/9/EC,

Annex II, 1.0.6.)

The following instructions apply to the Bray

International S52 2N1ProxSensor Valve Status

Monitor Part 521003-71114536 Intrinsically Safe

covered by certificate number Sira 11ATEX2134X.

Translations into other languages are available on

request.

1. The equipment may be used with flammable

gases and vapours with apparatus Gas Groups

IIA, IIB and IIC in Zone 0, 1 or 2 locations.

2. The equipment Temperature Class is T4 and is

only certified for use in ambient temperatures

in the range -20°C to +70°C and should not be

used outside this range.

3. Installation shall be carried out in accordance

with the applicable code of practice by suitably-

trained personnel.

4. Repair of this equipment shall be carried out in

accordance with the applicable code of practice.

5. The X suffix to the certificate number is to

indicate that there is a special condition for safe

use, which is regarding the potential build up of

static electricity and the precautions to be taken.

6. If the equipment is likely to come into

contact with aggressive substances, then

it is the responsibility of the user to take

suitable precautions that prevent it from being

adversely affected, thus ensuring that the type

of protection is not compromised.

Aggressive substances - e.g. acidic liquids or gases

that may attack metals, or solvents that may affect

polymeric materials.
Suitable precautions - e.g. regular checks as part

of routine inspections or establishing from the

material’s data sheet that it is resistant to specific

chemicals.
Copy of Certificate number Sira 11ATEX2134X