Frequently asked questions cont’d, Flow & pressure information, Pressure drop vs. flow for p to a or b – BRAND Hydraulics TS DIRECTIONAL CONTROL VALVES User Manual

Page 2: Pressure drop vs. flow for a or b to t, Neutral flow pressure drop, Pressure vs. flow for area-differ. port relief (b)

Advertising
background image

05/14

Pressure Drop vs. Flow for P to A or B

0

50

100

150

200

250

300

1.0

3.0

6.0

9.0

12.0

15.0

18.0

20.0

Flow (gpm)

P

re

s

s

u

re

(

p

s

i)

0

3

7

10

14

17

21

3.8

11.3

22.7

34.0

45.4

56.7

68.0

75.6

Flow (lpm)

P

re

s

s

u

re

(

b

a

r)

Pressure drop is the difference
between the inlet pressure and
port A or B of any section on a
TS1, TS2 or TS3.

Pressure Drop vs. Flow for A or B to T

0

5

10

15

20

25

30

35

1.0

3.0

6.0

9.0

12.0

15.0

18.0

20.0

Flow (gpm)

P

re

s

s

u

re

D

ro

p

(

p

s

i)

0.0

0.3

0.7

1.0

1.4

1.7

2.1

2.4

3.8

11.3

22.7

34.0

45.4

56.7

68.0

75.6

Flow (lpm)

P

re

s

s

u

re

D

ro

p

(

b

a

r)

Pressure drop is the difference
between the port A or B of any
section on a TS1, TS2 or TS3
and the outlet.

Neutral Flow Pressure Drop

0

5

10

15

20

25

30

35

40

45

1.0

3.0

6.0

9.0

12.0

15.0

18.0

20.0

Flow (gpm)

P

re

s

s

u

re

(

p

s

i)

0.0

0.3

0.7

1.0

1.4

1.7

2.1

2.4

2.8

3.1

3.8

11.3

22.7

34.0

45.4

56.7

68.0

75.6

Flow (lpm)

P

re

s

s

u

re

(

b

a

r)

This curve represents the
pressure difference between
the inlet and the outlet.

Pressure vs. Flow for Area-Differ. Port Relief (B)

0

500

1000

1500

2000

2500

3000

3500

1.0

3.0

6.0

9.0

12.0

15.0

18.0

Flow (gpm)

P

re

s

s

u

re

(

p

s

i)

0

34

69

103

138

172

207

241

3.8

11.3

22.7

34.0

45.4

56.7

68.0

Flow (lpm)

P

re

s

s

u

re

(

b

a

r)

DC7594 Spring (Yellow)

P1279 Spring (White)

P1270-360 Spring (Orange)

P1270 Spring (Yellow)

Relief is set at 6 gpm

TS315

PORT

12SAE OUTLET

3

2

1

FREQUENTLY ASKED QUESTIONS cont’d:

Q: Can I plumb another valve downstream from this valve, using the outlet of this valve?
A: You cannot plumb direct to another valve, unless your valve is equipped with
power beyond or has been converted to use power beyond. A valve can be ordered
with power beyond already set up by adding a W to the end of the model code.

Converting valve to “Power Beyond” – To convert the valve to power
beyond operation, take the TS315 plug from the top port (1) and insert it
into the internal port (2). Next, plumb a #10 SAE fitting from the top
port (1) to the adjoining valve. Lastly, run a line from the #12 SAE
outlet port (3) to the reservoir. (See illustration right )

Q: Can I convert my valve to operate in a “Closed” system?
A: Yes. To have the casting in closed center operation, both the top port (1) and internal port (2) must be plugged. Remove
the TS315 plug from the top port (1) and insert it into the internal port (2). Then plug the top port (1) with any std. SAE plug
(7/8 – 14) or purchase a plug from the factory. Closed center blocks “Pump” only, the condition of ports A and B depend on
the spool type. (See illustration above right)

Q: What kits are available for this valve?
A: There is a replacement seal kit (Part #: TS-K), and replacement relief kit (Part #: 34R15) for this valve. There are also a
number of different kits available for this valve depending on the spool action, and handle option the valve is equipped with.
Please contact factory for specific kit numbers relating to different spool actions, and handle options.

FLOW & PRESSURE INFORMATION:






















Advertising