Dings Magnetic Group Self-Cleaning Electro Overhead Magnets User Manual

Page 11

Advertising
background image

Revised May 19, 2014

DRIVE ASSEMBLY
GEARMOTOR - Inspect motor at regular intervals. Keep motor clean and the ventilation
openings clear of dust or other debris. See attached Nord Gear manuals for specific
information.

BEARINGS
LUBRICATION - If conditions are clean, lubricate every 2 to 6 months. If dirty, lubricate every
2 weeks or on a schedule consistent with other equipment in the same environment. Lubricate
with lithium based grease conforming to NLGI Grade 2.
GENERAL - Periodically check hex head set screws and bearing bolts for tightness, tighten if
loose.

SELF-CLEANING BELT
BELT - Periodically inspect for signs of wear and the vulcanized bond of the cleats. If belt
replacement instructions are needed, contact factory.
FASTENERS - Periodically check for wear, especially on the underside. If fastener
replacement instructions are needed, contact factory.
TRACKING - If belt needs to be retracked, refer to belt tracking section below.

ZERO SPEED SWITCH (Optional)
Periodic inspection of the shaft seal is recommended. Bearings of the permanently lubricated
type.

PULLEY/SHAFT ASSEMBLIES
All crown curved pulley compression hubs are properly tightened to the manufacturers’
recommended torque at the factory. Shortly after initial start-up, the hub bolts should be
retightened to the following torques:
Shaft

Diameter

Torque

1

15/16”

180

in.

lbs.

2

3/16” 180

in.

lbs.

2

7/16” 180

in.

lbs.

2

15/16”

360

in.

lbs

Check every 2 to 6 months and retighten as needed.