Dings Magnetic Group Self-Cleaning Electro Overhead Magnets User Manual

Page 15

Advertising
background image

Revised May 19, 2014

STEP 5

Turn off and lock-out the power to the rectifier. Disconnect the two leads from the rectifier to
the magnet at the magnet box terminals, using caution not to rotate the studs in the feed
through terminals as the internal connections may be damaged. The magnet must be cold for
the following tests. Using the watts and the volts from the nameplate on the magnet, square
the nameplate DC volts (115 VDC or 230 VDC) and divide by the nameplate watts to get the
target ohm reading. Measure the ohms between the two magnet box terminals.

VOLTS:

NOTE: There is no polarity for the magnet terminal posts. Either lead can be connected to
either terminal.

If the ohm reading is within + 10% of the target ohm reading, go to Step 6. If the ohm reading
is out of tolerance or infinity, consult the factory, supplying all of the above readings that were
taken.

STEP 6

Measure the ohm reading between one of the magnet box terminals and the magnet housing,
(The preferred measuring instrument is a megger.)

OHMS:

If the reading is one megohm (1,000,000 ohms) or larger, the magnet is OK. If the megger
ohm reading is out of tolerance, consult the factory, supplying all of the above readings that
were taken.

If it has been determined that the rectifier and the magnetic separator are electrically sound
and the performance of the separator is still in doubt, contact the factory for further assistance.
There are many factors which can affect the ability of a separator to attract metal.

SIGNIFICANCE OF ELECTRICAL READINGS:

Low DC Volts

Magnet will be weak


Low Ohms (resistance)

Possible shorted turns in coils


High Ohms

Possible poor connection or open coil circuit


Low DC Amps

Possible poor connection or open coil circuit


High DC Amps

Possible shorted turns in coils


Megger Reading Less

One or more coils are grounded, poor insulation or

Than 1 Megohm

transformer oil is contaminated with water

13

Advertising