10 Configuration

Configuring the channel Knock Voltage

y

On

the

Adjust

menu click Sensor Setup

y

Click

Input Setup…

this will open the Input Pins Setup screen

y

Click

the

Other

tab

y

Select

Knock Voltage (Knock V)

y

Click

Change

y

In

the

Input Source

list click AV[#] or Lambda[#] (Select the

input the SKM//OKM is wired to)

y

In

the

Calibration

area select Predefined and in the list click

#31 Volts(V); x1 (5.000V=5.000V)

Knock Gain Table

y

On

the

Adjust

menu click Functions

y

Click

Knock Control

y

Click

Gain

This table compensates any sensitivity differences of the sensor to
particular cylinders.
The Knock Gain table should be used in conjunction with the Knock
Offset table to level out any differences between the individual
cylinders.
Typical starting value: 1.00
Note:

The values in this table must be non-zero to show any Knock

Percentage values.

Data Logging Setup

Each cylinder's knock input should be logged at 50 Hz or greater.
• On

the

Adjust

menu click Data Logging Setup

• Click

Knock Levels

• Select

Knock Limit

and type 10

• Select Knock 1 and type 50 (or greater)
• Continue the last step for all remaining cylinders in firing order
Follow the same procedure to log other useful channels.
Recommended channels are:
y

Knock Retard Short Term for each cylinder

y

Knock Retard Long Term for each cylinder

y

Individual Ignition Advance channels - to evaluate the

performance of the control system during calibration tuning.