Table 3.6 gas data, 1) based on 1013.25 mbar and 15oc, 5 installation diagram – A.O. Smith BFC - 28 User Manual

Page 23: Installation diagram

Advertising
background image

Installation diagram

Release R.1.3 UK

23

is

Table 3.6 Gas data

3.5

Installation diagram

Figure 3.3

shows the water and gas connection diagrams for unvented and

vented installations. The following paragraphs, describing the connections in
detail, make reference to these diagrams

Gas category data

II

2H3+

Unit

BFC 28

BFC 30

BFC 50

BFC 60

Data for natural gas 2H: G20-20 mbar

Orifice diameter

mm

4.90

5.10

7.00

7.10

Nominal load (upper value)

kW

32.1

34.5

52.6

63.2

Nominal capacity

kW

30.3

32.8

48.6

59.6

Supply pressure

mbar

20

20

20

20

Burner pressure

mbar

8.5

8.5

8.5

11.5

Gas consumption

(1)

m

3

/h

3.1

3.3

5.0

6.0

Data for LP gas 3+

General

Orifice diameter

mm

2.50

2.60

3.40

3.80

Restrictor diameter

mm

n.a.

n.a.

n.a.

n.a.

G30-30 mbar (butane)

Nominal load (upper value)

kW

30.7

32.8

50.6

59.4

Supply pressure

mbar

37

37

37

37

Burner pressure

(2)

mbar

37

37

37

37

Gas consumption

(1)

kg/h

2.2

2.4

3.7

4.3

G31-37 mbar (butane)

Nominal load (upper value)

kW

29.0

30.9

50.3

59.1

Supply pressure

mbar

37

37

37

37

Burner pressure

(2)

mbar

37

37

37

37

Gas consumption

(1)

kg/h

2.1

2.2

3.6

4.2

(1) Based on 1013.25 mbar and 15

o

C.

(2) If using a flat sealing plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to the supply pressure.

In practice however, the burner pressure will be lower.