1 self-diagnostics, 2 calibration, English – CEMB USA C29 User Manual User Manual

Page 12

Advertising
background image

12

Use and maintenance manual Rev. 04-2010

ENGLISH

6.1.1 Self-diagnostics

The machine can perform self-diagnostics to check the
LED's on the control panel and make sure the encoder
reads correctly.

To perform this operation, view the SETUP menu.

In the self-diagnostics sequence, all the LED's on the panel
light up for a few seconds in order to check operation. When
the LED's go out, the machine automatically moves on to the
encoder reading phase. When the wheel is turned manually
(forwards and backwards), the display shows its exact posi-
tion. The value lies between 0 (zero) and 255.

6.1.2 Calibration

To calibrate the machine, proceed as follows:

Fit an average size wheel with a metal rim on the shaft.

Example: 6” x 15” (± 1”).
Set the wheel measurements as described in paragraph

SETTING WHEEL DIMENSIONS.

CAUTION

S

ETTING

INCORRECT

DIMENSIONS

WOULD

MEAN

THAT

THE

MACHINE

IS

NOT

CORRECTLY

CALIBRATED

, T

HEREFORE

,

ALL

SUBSEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

CALIBRATION

IS

PER

-

FORMED

ONCE

AGAIN

WITH

THE

CORRECT

DIMENSIONS

.

Display the SETUP menu:

Press

1.

or

to view view the CALIBRATION

function.

A

2. dd a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

Sh

3.

ift the standard weight from the outside to the

inside keeping the same position.

Tu

4.

rn the wheel until the standard weight is at the top

(12

o'clock).

End of calibration.

5.

To cancel calibration at any time, press

.

Setup

Perform a
manual spin

Perform a
manual spin

Perform a
manual spin