6.2

SELF-DIAGNOSTICS

The machine can perform self-diagnostics to check the
LED’s on the control panel and make sure the encoder
reads correctly.

To perform this operation, view the SETUP menu.

In the self-diagnostics sequence, all the LED’s on the pa-
nel light up for a few seconds in order to check operation.
When the LED’s go out, the machine automatically moves
on to the encoder reading phase. When the wheel is turned
manually (forwards and backwards), the display shows its
exact position. The value lies between 0 (zero) and 255.

6.3

CALIBRATION

To calibrate the machine, proceed as follows:

Fit an average size wheel with a metal rim on the shaft.

Example: 6” x 15” (± 1”).
Set the wheel measurements as described in paragraph

USE OF THE WHEEL BALANCER.

CAUTION

S

ETTING

INCORRECT

DIMENSIONS

WOULD

MEAN

THAT

THE

MACHINE

IS

NOT

CORRECTLY

CALIBRATED

, T

HEREFORE

,

ALL

SUBSEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

CALIBRATION

IS

PER

-

FORMED

ONCE

AGAIN

WITH

THE

CORRECT

DIMENSIONS

.

Display the SETUP menu:

P

1. ress

to view the CALIBRATION

function.

A

2. dd a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

Sh

3.

ift the standard weight from the outside to the

inside keeping the same position.

Tu

4.

rn the wheel until the standard weight is at the top

(12

o’clock).

End of calibration.

5.

To cancel calibration at any time, press

.

6.4

AUTOMATIC GAUGES CALIBRATION

6.4.1 Rim distance gauge

Display the SETUP menu

P

1. ress

to view the rim distance

gauge CALIBRATION function.

Leave the distance gauge in rest position and press

2.

Setup

Br

3.

ing the gauge in line with the adapter flange and

press