Use of the wheel balancer

5.1

PRESETTING OF WHEEL DIMENSIONS

The balancing data is set by means of an “intelligent” au-
tomatic gauge; confi rmation of the measurement and the
position appear on the display. The round part of the gauge
must rest on the rim where the weight will be positioned.

While the gauge is moving the following appears:

when the measurement has been stored:

a) standard weights: when only one measurement is
made, the machine interprets the presence of a rim with

clip-on weight correction

The correct measurement is that which can be measured
with the compass gauge provided.

Use of the wheel balancer

b) adhesive weights: make two successive measurements

on two correction planes inside the rim.

The balancing machine automatically interprets that the
correction will be made with adhesive weights and the

following appears:

For a different combination of the type or position of the

weights on the rim, use the

button.

5.1.1 Modifying set dimensions

If the wheel dimensions have been entered incorrectly,
the parameters can be modified without repeating the
balancing spin by pressing for 2 seconds :

access parameter modifi cation

(select

to modify: (a) distance, (b) width, (d)

diameter

In the case of standard weights:

(a)distance,(b)width,(d)diameter

In the case of adhesive weights:

(a1) inside distance,(a2) outside distance,(d1) inside

diameter,(d2) outside diameter

press

to select (a) (b) or (d)

to recalculate the unbalance

or:

pull out the gauge to repeat the measurement

to obtain the new measurement.