6.5

CALIBRATION

To calibrate the machine, proceed as follows:

▪ Fit an average size wheel with a metal rim on the shaft.

Example: 6” x 15” (± 1”).

▪ Set the wheel measurements as described in paragraph

USE OF THE WHEEL BALANCER.

cAuTIoN

s

eTTING

INcoRRecT

dImeNsIoNs

Would

meAN

ThAT

The

mAchINe

Is

NoT

coRRecTly

cAlIbRATed

, T

heRefoRe

,

All

subsequeNT

meAsuRemeNTs

WIll

be

INcoRRecT

uNTIl

cAlIbRATIoN

Is

peR

-

foRmed

oNce

AGAIN

WITh

The

coRRecT

dImeNsIoNs

.

Display the SETUP menu:

1. Press

to view the CALIBRATION

function.

2. Add a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

3. Shift the standard weight from the outside to the

inside keeping the same position.

4. Turn the wheel until the standard weight is at the top

(12 o’clock).

5. Turn the wheel until the sample weight is in corre-

spondence to the centre-line of the weight clip.

Pressing the button

a default value is set.

6. Turn the wheel until the centre-line of the sample

weight is in correspondence to the laser beam.

Pressing the button

a default value is set.

7. End of calibration.

To cancel calibration at any time, press

.

6.6

AUTOMATIC GAUGES CALIBRATION

6.6.1 Rim distance gauge

Display the SETUP menu

1. Press

to view the rim distance

gauge CALIBRATION function.

2. Leave the distance gauge in rest position and press

3. Bring the gauge in line with the adapter flange and

press

CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.