Ba d, Lettura – CEMB USA C65 (E) User Manual
Page 12

I 0206 - 12
b
a
d
Lettura
GB
5.3.3 - MANUAL PRESETTING
If necessary, the dimensions can be inserted or edited in manual mode as follows:
- press
+
4
or else press
6
from the Dimensions in automatic mode screen (which can be
reached by pulling out the distance + diameter gauge).
- press
to select the dimension to be preset .
- press
2
/
3
to preset the required value.
- press
5
to change unit of measurement.
- press
6
to preset the dimensions for the ALU-S correction mode
Definition of dimensions:
d = DIAMETER: Preset the nominal diameter stamped on the rim.
b = WIDTH: Preset the nominal width indicated on the rim.
a = DISTANCE: Preset the distance of the inside of the wheel from the machine, after measuring
it with relative gauge as described in fig. 8.
Fig. 10
Reading