6.2 - SELF-CALIBRATION
For machine self-calibration proceed as follows :
- Fit a metal wheel of average dimensions on the shaft. Example 6” x 14” (± 1”)
- Preset the exact dimensions of the wheel mounted.
CAUTION!! Presetting of incorrect dimensions would mean that the machine is not correctly calibrated,
therefore all subsequent measurements will be incorrect until a new self-calibration is
performed with the correct dimensions!!
- Perform a spin under normal conditions.
- Add 100 g. (3.5 oz) on the outside in any angular position.
- Shift the 100 g. weight from the outside to the inside keeping the same
angular position.
- Rotate the wheel so to have the 100 g. weight to the 12 o’clock position.
END
OF
SELF-CALIBRATION
CANCEL SELF-CALIBRATION IN ANY PHASE