CEMB USA C218 (A) User Manual

Page 21

Advertising
background image

I 0568 - 21

GB

7.3.4 - Machine self-test

An automatic self-diagnostics cycle is provided for easier trouble shooting. At the end of the self-diagnostics cycle,
several parameters are displayed which are useful for the Technical Service Department in order to identify machine faults.

Returns to previous menu.

7.3.4.1 - To check the encoder

When the spindle is rotated:
- the angular position “POS” should vary from 0 to 128;
- the wording “UP” should appear when rotated clockwise and “DOWN” when rotated in the opposite direction.

Check for correct
operation of the
distance gauge; the
number increases
when the gauge is
pulled out.

Check of the eccentricity
sonar (option): the number
decreases when a surface
is approached to the sonar

Check encoder

In the event of failure or faulty operation of the wheel balancing machine, notify the Technical Service of all the
parameters displayed.

Advertising