5.2 - RESULT OF MEASUREMENT

Unbalance display pitch:

Car = 1/5 g (.1/0.25 Oz) Truck = 10/50 g (.25/1 Oz)

When

is pressed, the unbalance is displayed with pitch:

Car = 1 g

Truck = 10 g

.1

Oz

.25

Oz

Unbalance display threshold

Car = 5 g (.4 Oz)

Truck = 50 g (2 Oz)

Inside correction

Outside correction

After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.
Digital readouts with LED lit up indicate the correct angular wheel position to mount the counterweights (12 o’clock
positi

on).

If the unbalance is less than the threshold selected,

0

is displayed instead of the unbalance; with

it is possible

to read the values below the threshold chosen.

5.2.1 - STATIC UNBALANCE

It is selected by pressing

and is shown on the central display. The position is indicated on the displays 3 and 4.

The value can always be displayed (see

SETUP

); in this case, to see the position press

.

5.2.2 -

MODIFYING SET DIMENSIONS

If the wheel dimensions have been entered incorrectly, the parameters can be modifi ed without repeating the balan-
cing spin by pressing :

access parameter modifi cation

(select

to modify: (a) distance, (b) width, (d) diameter

to obtain the new measurement

or:

pull out the gauge to repeat the measurement

to obtain the new measurement.

5

.2.3 -

EXACT POSITIONING OF THE ADHESIVE WEIGHT BY MEANS OF THE GAUGE WITH CLIPS

Press

Fit

the correction weight in the specifi c gauge seat with the

adhesive part facing upwards

Bring the wheel into correct angular position for the plane


to be corrected
Pull out the gauge: the approach of the weights to the correc-


tion positions is indicated by the LEDs number 19
When the weight application distance has been reached a beep


is sounded (can be deactivated).
Turn the gauge until the correction weight adheres to the rim


using the weight pusher.