I 0186 GB - 21
0
6.3.3 - WIDTH GAUGE (OPTIONAL)
Set with
the distance in mm between the
SONAR sensor and the distance gauge clamp in pos.
0.
Set with
the distance in mm between the
SONAR sensor and the side of the tyre used for calibra-
tion.
SLOWLY lower the guard
until it completely closes.
Wait until the matrix display (
EXTRA SAFETY DEVICES
) shows the up
arrows
and then completely re-open the guard.
Repeat the sequence for the number of times
indicated on display 2.
- In the event of incorrect input in the width gauge calibration function, press
.