CM2C40

Installation Instructions

24

Troubleshooting

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Lift does not respond

No Power to Mount

12V trigger option being
used

Overheated motor

Verify Power to Mount

Normal Operation
See "Low Voltage Sensing" section

Allow motor to cool for 10 to 15
minutes

SW1

Switch 1

IR

Switch 2

IR

Switch 3

IR

Switch 4

Not Used

Switch 5

Not Used

Switch 6

485 Address

Switch 7

485 Address

Switch 8

485 Address

IR System Code Select Logic

Switch Settings (Sw 1-3)

Select 2

Select 1

Select 0

IR System Code

OFF

OFF

OFF

6E

OFF

OFF

ON

E1

OFF

ON

OFF

E2

OFF

ON

ON

E3

ON

OFF

OFF

E4

ON

OFF

ON

E5

ON

ON

OFF

E6

ON

ON

ON

E7

RS485 Address Select Logic

Switch Settings (Sw 6-8)

Select 2

Select 1

Select 0

RS485 Network

Address

OFF

OFF

OFF

00

OFF

OFF

ON

01

OFF

ON

OFF

02

OFF

ON

ON

03

ON

OFF

OFF

04

ON

OFF

ON

05

ON

ON

OFF

06

ON

ON

ON

07