Out 2– non-isolated, Signal ground, Video iris – ALLIED Vision Technologies Prosilica GS2450 User Manual

Page 32: Reserved, Signal ground video iris reserved

Advertising
background image

Prosilica GS Technical Manual V2.0.5

32

Camera interfaces

Out 2– non-isolated

Out 2 signal is not electrically isolated and can be used when environmental
electrical noise is inconsequential and faster trigger response is required. Use
Signal GND to complete the external circuit. The output signal is a low voltage
TTL, maximum 3.3 V
. Not suitable for driving loads in excess of 24 mA. See

Camera I/O non-isolated user circuit example

for more wiring information.

Signal ground

Signal Ground must be connected to the user’s external circuit ground if In 2 or
Out 2 is to be used, or if the RS-232 port is to be used. Note that Signal Ground
is common with Camera GND; however, it is good practice to provide a separate
ground connection for power and signal.

Video iris

This signal can be used to drive the video input of a video iris lens. See

Video iris

user circuit example

section for wiring information.

Reserved

These signals are reserved for future use and should be left disconnected.