Camera i/o opto-isolated user circuit example, Camera i, O opto-isolated user circuit example – ALLIED Vision Technologies Prosilica GS2450 User Manual

Page 33

Advertising
background image

Prosilica GS Technical Manual V2.0.5

33

Camera interfaces

Camera I/O opto-isolated user circuit example

*Cameras with SN: 02-XXXXX-0XXXX, R1 necessary for input greater than 5 V,
see table above. Cameras with SN: 02-XXXXX-1XXXX, no R1 is necessary, 5–24 V.

Isolated output is connected to the open collector of Fairchild MOCD207. The
corresponding transistor emitter is connected to isolated ground. See the Fair-
child MOCD207 datasheet for more detailed information.

Figure 16: Prosilica GS isolated trigger user circuit

Caution

Input: Incoming trigger must be able to source 10 mA.

Output: User power, with pull-up resistor R2 is required.

User Power

CABLE SIDE

Isolated GND

In1

Camera GND

In1

3M 10114-3000PE

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Out1

Out1

Camera GND

R2

Camera Power

Camera Power

R1

USER

POWER

RECOMMENDED VALUES

R1

R2

5 V

0

1 K Ω

12 V

0.7 KΩ

2.7 KΩ

24 V

1.8 KΩ

4.7 KΩ

Advertising
This manual is related to the following products: