If you need to use your own Software Control program from a

PC or automation, the device allows communication through

an ASCII code protocol. All commands can be found on our

website:

www.analogway.com

All Analog Way products equipped with an RS232 input are

compatible with Crestron, AMX, Medialon, and most major

control systems. TCP/IP control ports are also available on

most Analog Way products, as standard or as options.

To control an

OPS200

product with an External Remote

Controller (PC Software Control - Touch Pad Controller…)

follow the indications below:
1. First establish an RS-232 communication between the

Remote Control Software and the

OPS200

, in order to setup

the LAN parameters of the product.

2. In the “Control” - “OPS200 LAN Setup” menu, configure the

connection of the

OPS200

product in UDP mode and setup

the Local and Remote Addresses as well as the Local and

Remote Ports in concordance with your Network.

3. Configure the TCP/IP address of your External Remote

Controller.

In example: 192.168.000.001

4. Setup the UDP connection of your External Remote

Controller in concordance with your Network.
In example on the Remote Software in the “Control” - “RS232/

LAN Setup” - “LAN/Setup” menu.

5. Setup the LAN parameters in UDP mode in the “Console” -

“LAN Setup” menu.

In example:

RK Address:

192.168.000.002

Remote Address:

192.168.000.010

Gateway

Address:

192.168.000.001

RK Port:

10500

Remote Port:

10500

Netmask:

255.255.255.000

6. Select the LAN communication port in the remote controller

console - “RS232/LAN port” menu.

7. You can now control your

OPS200

product with an External

Remote Controller.

7-3. EXTERNAL PROGRAMMING