5.2 Data exchange in normal operation
With the manufacturer-specific versions BEI
IDEACOD 2.2 the process value generally is
transmitted as 32-bit-value (peripheral double
word). Apart from 25 bits used for the position
value the 7 other bits are used as status bits.
The output double word contains the preset
value and control bits.
Absolute encoders model series might have
(physical) position values > 25 Bit. The
manufacturer specific BEI IDEACOD versions
do not support the position values > 25 Bit. The
upper digits will be overwritten by the status
bits. If the BEI IDEACOD versions are used with
encoders with a total (physical) resolution > 25
Bit, the user has to assure that the position
value is scaled to a maximum output value <
33554432. If position values > 25 Bit are
necessary class 2 should be used.
If version BEI IDEACOD 2.2 is used the current
velocity is transmitted in an additional
(peripheral) input word.
ID
F1 hex
D0 hex
Status + position value
Velocity
Slave Master
Status + 2
24
2
23
- 2
16
2
15
- 2
8
2
7
- 2
0
2
15
- 2
8
2
7
- 2
0
Preset value + control bits
Master slave
Control + 2
24
2
23
- 2
16
2
15
- 2
8
2
7
- 2
0
Meaning of the different status bits:
Bit 28 Bit 27 Bit 26 Bit 25 Meaning
Ready
0 = encoder is not ready for operation
1 = encoder is ready for operation
Mode
0 = commissioning mode
1 = normal mode
Software limit switch
0 = lower limit switch current position value upper limit
switch
1 = current position value > upper limit switch or
current position value < lower limit switch
Code sequence
0 = increasing clockwise (view onto the shaft)
1 = increasing counter clockwise (view onto the shaft)