BEI Sensors Industrial Duty Inclinometers User Manual

Page 3

Advertising
background image

Page 3

CANopen Industrial Datasheet

Version 20130503

INDUST RIAL I NCLI NOME T ER

CA NOPE N INT ERFA CE

MTBF Data

Failure Rate [FIT]

759

MTBF [Hours]

1,317,822

MTBF [Years]

150

The above mentioned data were calculated for electronics under the following conditions:

SNA: Non-mobile operation

Tu: 40°C - Mean component of ambient temperature

Zf: Continuous operation for 8760 h per year

Programmable Parameters

Resolution per 1°

The resolution parameter per 1° is used to program the desired

number (1°, 0.1° and 0.01°) of steps per 1°.

Preset Value

The Preset value is the desired position value, which should be

reached at a certain physical position of the axis. The position

value is set to the desired process value by the preset parameter.

Moving Avarage-Filter

This filter can be used to adjust the bandwidth of measuring

values to minimize the influence of vibration. Factory Setting:

Moving average filter activated for 20 subsequent readouts.

Digital Recursive Filter

This filter can be used for weighting the last measured value with

the last previous value. This is useful to suppress sudden peaks in

the angle measurement.

Transmission Rate

Adjustable - Min. 20 kBaud; Max. 1 MBaud

Factory Setting : 125 kBaud

Address (Node ID)

Adjustable from 1 to 127

Factory setting: Node ID=1


Advertising