CANopen Industrial Datasheet

Version 20130503

INDUST RIAL I NCLI NOME T ER

CA NOPE N INT ERFA CE


Programmable CAN Transmission Modes

Polled Mode

By a remote-transmission-request telegram, the connected host

calls for the current process value. The inclinometer reads the

current position value, calculates eventually set-parameters and

sends back the obtained process value by the same identifier.

Cyclic Mode

The inclinometer transmits cyclically the current process value,

without being called by the host. The cycle time can be

programmed in milliseconds for values between 1 ms and

65536 ms.

Sync Mode

The inclinometer answers with current process value after

receiving a sync telegram. The parameter sync counter can be

programmed to skip a certain number of sync telegrams before

answering again.

Heartbeat Function

A node signals its communication status by cyclically transmitting

a heartbeat message. This message is received by one or any

number of members (Heartbeat Consumers) in the bus and so

they can control the dedicated node (Heartbeat Producer).