Communications Settings

Dip Switch Settings

The Datamax-O’Neil printers support Serial RS232, IrDA compatible infrared communication interfaces and
USB*

1

.Bluetooth™ and Wi-Fi communication are also available as an optional feature. Serial/USB IrDA, Wi-Fi and

Bluetooth™ communication settings can be changed via a DIP switch located on the control card. In the following
sections each setting is discussed in more detail.

Function (APEX2,3,4)

Switch #

Notes

Communication Interface SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8

RS232

OFF

OFF

Baud rate set by Dip switches 3,4

and 5

1

IrDA

ON

OFF

Baud Rate can be negotiated up to

the value specified through Dip

switches 3,4 and 5

Bluetooth or 802.11g

OFF

ON

N/A

ON ON

Setting not supported

2

USB

X

X

OFF

OFF

ON

3

USB Bootloader

X

X

ON

OFF

ON

4

Baud Rate

SW 3

SW 4

SW 5

RS232 and IrDA only

115200

OFF

OFF

OFF

57600

ON

OFF

OFF

38400

OFF

ON

OFF

19200

ON ON

OFF

14400

OFF

OFF

ON

9600

ON

OFF

ON

Use for fixed IrDA

2400

OFF

ON ON

1200

ON ON ON

Parity Bit

SW 6

SW 7

Parity Enabled (ODD)

ON

ON

Does not apply for IrDA

Parity Enabled (EVEN)

ON

OFF

Does not apply for IrDA

Auto Power Save

SW 8

Power Save Enabled

ON

Auto Power Down

Power Save Disabled

OFF

Manual On/Off

1

If IrDA is not installed, printer will default to RS232 mode with baud rate 115200

2

X

stands for Don’t Care: Dip Switch 7 will override 1 and 2

3

Firmware Applies to Apex 4 - Version 1.10 or later, Check availability for other printer models

4

Baud Rate and Parity are applicable to RS232 and IrDA communication mode ONLY

Advertising