Data Input

Data Input is in the form of System and Label Formatting commands, where <STX>KcRI and
<STX>KcQQQ support the entries that are shown in Menu mode. The RFID database file (RFID_DB)
resides on the Y module. It stores RFID information and should not be deleted. If not found at power-up
then factory defaults will be set. <STX>KcRIa configures the RFID interface, as noted below:


Value

Units / Interpretation

RFID Configuration Definition / Function

D = Disable

Disables the RFID module. (“N” is also a valid disabler.)

H = HF

Enables the RFID module for HF (Securakey).

U = UHF

Enables the RFID module for UHF Class 1 (Alien).

Mn

where n:

M = UHF

Enables the RFID module for UHF Multi-Protocol (Samsys).

AIhh

where hh:

2-Chararacter Hex ID

Sets the Application Family Identifier (AFI), (HF only)

ALn

where n:

E = Enable,

D = Disable

Allows locking the AFI after writing (HF only)

DIhh

where hh:

2-Chararacter Hex ID

Sets the Data Storage Format Identifier (DSFID), (HF only)

DLn

where n:

E = Enable,

D = Disable

Allows locking the DSFID after writing (HF only)

Shh

where hh:

2-Chararacter Hex ID

Sets the Electronic Article Surveillance (EAS) set, representing
the manufacturer’s code. (HF only)

Lhh

where hh:

2-Chararacter Hex ID

Sets the Lock Code (Alien UHF only)

Rn

where n:

0 – 9

Sets the number of retries for RFID functions

Wn

where n:

E = Enable,

D = Disable

Allows locking the tag after writing.

En

where n:

E = Enable,

D = Disable

Allows erasures of the tag on error (HF only)

Pxxx

where xxx:

Is a 3-digit value

Sets the tag encoding position: A value of 0.00 causes the print
position to be used; or, a value greater than 0 causes the
presented position to be used. (Subject to change.)

Tn

where n:

0 = ISO 15693
1 = Texas Instruments
2 = Philips
3 = ST Micro LRI 512
4 = ST Micro LRI 64

Establishes the tag type (HF only).

Nn where

n:

64 = 64-bit
96 = 96-bit

Sets the UHF tag data size (Samsys UHF only).

Un where

n:

0 = EPC 0
1 = EPC 0+ Matrics
2 = EPC 0+ Impinj
3 = EPC 1
4 = ISO 18000-6A
5 = ISO 18000-6B
6 = UCODE EPC 1.19
7 = EM 4022/4222
8 = Gen 2

Sets the UHF tag type (Samsys UHF only).

Vn where

n:

Is a value from -4 to +4 Adjusts the power, in dBmn (Samsys UHF only).