Reading out measured values

The various values measured by the appliance are displayed in the
#MEASURES

menu.

1. To access user level: Press the > key.
2. Select the menu #MEASURES.

4

Turn the rotary button to scroll through the menus or

modify a value.

4

Press the rotary button to access the menu selected

or confirm a value modification.

¼ For a detailed explanation of menu browsing, refer

to the chapter: "Browsing in the menus", page 11.

User level - #MEASURES menu

Parameter

Description

Unit

OUTSIDE TEMP.

Outside temperature

°C

ROOMTEMP. B

(1)

Room temperature of circuit B

°C

ROOMTEMP. C

(1)

Room temperature of circuit C

°C

BOILER TEMP.

(2)

Water temperature in the boiler

°C

WATER TEMP.

(1)

Water temperature in the DHW tank

°C

STOR.TANK.TEMP

(1)

Water temperature in the storage tank

°C

SWIMMING P.T.B

(1)

Water temperature of the swimming pool on circuit B

°C

SWIMMING P.T.C

(1)

Water temperature of the swimming pool on circuit C

°C

OUTLET TEMP. B

(1)

Temperature of the flow water in circuit B

°C

OUTLET TEMP. C

(1)

Temperature of the flow water in circuit C

°C

SYSTEM TEMP.

(1)

Temperature of the system flow water if multi-generator

°C

T.DHW BOTTOM

(1)

Water temperature in the bottom of the DHW tank

°C

TEMP.TANK AUX

(1)

Water temperature in the second DHW tank connected to the AUX circuit °C

TEMP.SOL.TANK

(1)(2)

Temperature of the hot water produced by solar power (TS)

°C

SOLAR.COLL.T.

(1)

(2)

Solar panel temperature (TC)

°C

SOLA.ENERGY

(1)

(2)

Solar energy accumulated in the tank

kWh

IN 0-10V

(1)(2)

Voltage at input 0-10 V

V

CTRL

Software control number

(1) The parameter is only displayed for the options, circuits or sensors actually connected.

(2) According to the configuration

bar

1

1

2

2

D

STD

J

I

E

0

2

4

6

8

10

12

14

16

18

22

24

20

#

F

AUTO

% $

<

:



!

SUNDAY 11:45